MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.13-12211

Медицинская библиотека · Investigative ophthalmology & visual science · 2013

Adjustment of the retinal angle in SD-OCT of glaucomatous eyes provides better intervisit reproducibility of peripapillary RNFL thickness.

Lee Kyungmoo, Sonka Milan, Kwon Young H, Garvin Mona K, Abràmoff Michael D

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

PURPOSE: To report an automated method for adjustment of the retinal angle in spectral-domain optical coherence tomography (SD-OCT) and compare its intervisit reproducibility of the peripapillary retinal nerve fiber layer (RNFL) thicknesses of glaucomatous eyes to that obtained by the Cirrus algorithm.

METHODS

Fifty-six glaucoma and glaucoma suspect subjects were repeatedly imaged, and optic nerve head (ONH)-centered OCT image volumes (200×200×1024 voxels, 6×6×2 mm3, Cirrus HD-OCT machine) were acquired within a 4-month period from one eye of the 56 patients. Retinal angle correction in B-scans was accomplished by adjusting the angle using the voxel aspect ratio of the SD-OCT followed by straightening of rotated A-scans. The RNFL layer was automatically segmented using the Iowa Reference Algorithm. Reproducibility of the peripapillary RNFL thicknesses was determined by intraclass correlation coefficient (ICC), coefficient of variation (CV), repeatability coefficient (RC), and 95% tolerance limit (TL) for the Iowa Reference Algorithm without and with the retinal angle correction and for the Cirrus algorithm (Cirrus version 5.1.0.96).

RESULTS

The angle corrected Iowa Reference Algorithm (ICC: 0.990, 95% confidence interval [CI]: 0.983-0.994) for peripapillary RNFL thicknesses showed significantly better reproducibility than the nonangle corrected algorithm (ICC: 0.964, 95% CI: 0.940-0.979) and the Cirrus algorithm (ICC: 0.960, 95% CI: 0.933-0.976) based on the 95% CIs for the ICCs.

CONCLUSIONS

Angle correction leads to more consistent peripapillary RNFL thicknesses. This may lead to improved management of patients with glaucoma.

Для цитирования: Lee Kyungmoo, Sonka Milan, Kwon Young H, Garvin Mona K, Abràmoff Michael D. Adjustment of the retinal angle in SD-OCT of glaucomatous eyes provides better intervisit reproducibility of peripapillary RNFL thickness.. Investigative ophthalmology & visual science. 2013. DOI: 10.1167/iovs.13-12211.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.