MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/joa3.12069

Медицинская библиотека · Journal of arrhythmia · 2018

A comparison of 8-mm and open-irrigated gold-tip catheters for typical atrial flutter ablation: Data from a prospective multicenter registry.

De Ruvo Ermenegildo, Sagone Antonio, Rovaris Giovanni, Marchese Procolo, Santamaria Matteo, Solimene Francesco, Rauhe Werner, Piazzi Elena, Moretti Luciano, Parisi Quintino, Schillaci Vincenzo, Pelissero Elisa, Manfrin Massimiliano, Giacopelli Daniele, Gargaro Alessio, Calò Leonardo, Senatore Gaetano

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Cavotricuspid isthmus (CTI) radiofrequency (RF) catheter ablation is the standard treatment for patients suffering from CTI-dependent atrial flutter (AFL). The aim of this study was to compare the use in clinical practice of 8-mm gold-tip catheter (8mmRFC) and open-irrigated gold-tip catheter (irrRFC) for RF typical AFL ablation.

METHODS

Patients with typical AFL were treated with 8mmRFC or irrRFC catheters according to investigator preferences. The primary endpoint was the cumulative radiofrequency time (CRFT). Fluoroscopy time, acute and 6-month success rates were secondary endpoints.

RESULTS

After excluding 3 patients with left AFL, 157 of the enrolled patients (median age 71.8 [interquartile range, 64.1-76.2], 76% men, 91% in NYHA class ≤II, 65% with no structural heart disease) were analyzed: 74 (47%) subjects were treated with the 8mmRFC and 83 (53%) with the irrRFC. The median CRFT was 3 [2-6] minutes in the 8mmRFC group and 5 [3-7] minutes in the irrRFC group (P = .183). There were no significant differences in ablation success rates, intraprocedural CTI reconnections, audible steam pops, and procedural times. In the 8mmRFC group, a significantly lower fluoroscopy time was observed as compared to the irrRFC group (8 [5-12] vs 15 [10-20] minutes, P < .001). During the follow-up period, AFL recurrences were documented in 3 patients in the 8mmRFC group and 2 in the irrRFC group (P = .655).

CONCLUSIONS

The 8mmRFC and the irrRFC performed similarly in routine practice for CTI ablation in terms of cumulative RF time, acute and 6-month success rates. Fluoroscopy time was significantly lower in the 8mmRFC group.

Для цитирования: De Ruvo Ermenegildo, Sagone Antonio, Rovaris Giovanni, Marchese Procolo, Santamaria Matteo, Solimene Francesco, Rauhe Werner, Piazzi Elena, Moretti Luciano, Parisi Quintino, Schillaci Vincenzo, Pelissero Elisa, Manfrin Massimiliano, Giacopelli Daniele, Gargaro Alessio, Calò Leonardo, Senatore Gaetano. A comparison of 8-mm and open-irrigated gold-tip catheters for typical atrial flutter ablation: Data from a prospective multicenter registry.. Journal of arrhythmia. 2018. DOI: 10.1002/joa3.12069.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.