8-0 Polypropylene Suture Looping and Overhand Knot: Transconjunctival Approach to Four-Point Scleral Fixation of an Akreos Adapt Intraocular Lens.

Chen Shijiu, Yuan Gongqiang, Zhu Wenhua, Shan Tianhui, Liu Chunli, Zhang Jingjing

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate a novel surgical technique for transscleral fixation of the intraocular lens (IOL) with four hollow haptics using 8-0 polypropylene suture looping and overhand knot.

METHODS

An 8-0 polypropylene suture was tied to a 10-0 polypropylene suture with an overhand knot. One set of 8-0 polypropylene suture was then passed through the IOL four haptics. The suture knot was buried by rotating into the sclera tunnel. Best-corrected visual acuity, intraocular pressure, and complications were determined.

RESULTS

The IOLs were fixed with using an 8-0 polypropylene suture in 13 eyes of 11 patients with aphakia and dislocated crystalline lens. The mean preoperative corrected distance visual acuity was 0.71 ± 0.58 logarithm of the minimum angle of resolution (Snellen 20/103), and it improved to 0.24 ± 0.25 logarithm of the minimum angle of resolution (Snellen 20/35) at the final follow-up ( P < 0.05). No vitreous hemorrhage, hypotony, suture exposed, and pupillary capture of the IOL were observed in any of the patients.

CONCLUSION

The authors have developed a new technique for transscleral IOL fixation with one set of an 8-0 polypropylene suture tied to a 10-0 polypropylene suture with an overhand knot. The overhand knot offers the opportunity to use an 8-0 polypropylene suture for the long-term safety and may not require the surgeon to learn any new technique.

Для цитирования: Chen Shijiu, Yuan Gongqiang, Zhu Wenhua, Shan Tianhui, Liu Chunli, Zhang Jingjing. 8-0 Polypropylene Suture Looping and Overhand Knot: Transconjunctival Approach to Four-Point Scleral Fixation of an Akreos Adapt Intraocular Lens.. Retina (Philadelphia, Pa.). 2020. DOI: 10.1097/iae.0000000000002873.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.