Pattern Electroretinography Changes in Patients with Established or Suspected Primary Open Angle Glaucoma.

Ganekal Sunil, Dorairaj Syril, Jhanji Vishal

СтатьяОбзорПеревод в очереди

Аннотация

PURPOSE: To assess pattern electroretinogram (PERG) changes in patients with established or suspected primary open angle glaucoma (POAG).

MATERIALS AND

METHODS

Transient PERG using LV Prasad eye electrodes were performed in 76 normal, 32 glaucomatous and 22 glaucoma suspect eyes. The P50 amplitude, N95 amplitude and P50 latency were analyzed. The results were further analyzed with receiver operating characteristic (ROC) curves and discriminant function analysis (DFA).

RESULTS

The P50 and N95 amplitude of the POAG and glaucoma suspect groups were significantly reduced. There was significant shortening in the P50 latency in the POAG and glaucoma suspect groups. DFA using the P50 amplitude, N95 amplitude and P50 latency waveform parameters showed a sensitivity and specificity of 76.67 and 88.57% respectively.

CONCLUSION

Pattern ERG demonstrated significant changes in POAG patients and suspects. ROC curves for the three wave parameters demonstrated that N95 amplitude was the better indicator for diagnosis of POAG when used individually. How to cite this article: Ganekal S, Dorairaj S, Jhanji V. Pattern Electroretinography Changes in Patients with Established or Suspected Primary Open Angle Glaucoma. J Current Glau Prac 2013;7(2):39-42.

Для цитирования: Ganekal Sunil, Dorairaj Syril, Jhanji Vishal. Pattern Electroretinography Changes in Patients with Established or Suspected Primary Open Angle Glaucoma.. Journal of current glaucoma practice. 2013. DOI: 10.5005/jp-journals-10008-1135.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.