A case report of balloon-assisted tracking to overcome coronary sinus competent valve: a novel technique in left ventricular lead implantation.
Аннотация
BACKGROUND
Competent lateral and posterolateral valves showed proximal tortuosity that might hinder left ventricular (LV) lead implantation in cardiac resynchronization therapy (CRT).
CASE SUMMARY: A 57-year-old woman was diagnosed as non-ischaemic cardiomyopathy, no other comorbidities, complaining of dyspnoea [New York Heart Association (NYHA) class III], and on optimal medical therapy. Electrocardiogram showed left bundle branch block with QRS duration 150 ms. The patient was candidate for CRT. However, during LV lead implantation, a competent posterolateral vein valve and proximal tortuosity hindered LV lead implantation that was overcome by balloon-assisted tracking technique. At 9 months of follow-up, the patient had NYHA class II, ejection fraction improved to 38%, and all implanted leads were still in place.
DISCUSSION: Balloon-assisted tracking technique can be used to cross coronary sinus and smaller veins with competent valves and coronary veins tortuosity.