MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3760/cma.j.cn112147-20201123-01113

Медицинская библиотека · Zhonghua jie he he hu xi za zhi = Zhonghua jiehe he huxi zazhi = Chinese journal of tuberculosis and respiratory diseases · 2021

[Diagnostic value of the combinations of bronchoalveolar lavage fluid pathogen detection and cryptococcal antigen test in pulmonary cryptococcosis].

Yan Q F, Sun Z L, Gao Y, Xiao T, Lin H, Ji M

СтатьяПеревод в очереди

Аннотация

Objective

To evaluate the diagnostic value of bronchoalveolar lavage fluid pathogen detection combined with cryptococcal antigen test(CrAg) for pulmonary cryptococcosis(PC).

Methods

A retrospective case analysis was performed on non-acquired immunodeficiency syndrome patients admitted to Ninghai First Hospital for suspected PC from January 2018 to December 2019. Fifty-nine patients were included. Sixteen cases (8 males and 8 females) were diagnosed with PC, aged from 18 to 76 years[an average age of (52±14) years], while 43 cases were diagnosed as having Non-PC. All patients had undergone both serum CrAg test and BALF pathogen detection(cultures and direct examination) combined with BALF-CrAg test. The sensitivity and specificity of the combined method of BALF was evaluated, and a parallel comparison of the diagnostic efficiencies of the two methods were made.

Results

Of the 16 confirmed PC cases, serum CrAg tests were positive in 11 and negative in 5 cases, while the combined method showed that 14 were positive and 2 were negative. Compared with the clinical final diagnosis, the sensitivity, specificity, positive predictive value and negative predictive value showed that the serum CrAg tests were 68.8% (11/16), 97.7% (42/43), 91.7% (11/12), 89.3% (42/47) respectively, versus 87.5% (14/16), 100.0% (43/43), 100% (14/14), 95.6% (43/45) by the combined method of BALF. The results displayed no statistical difference between the two diagnostic methods (P =1.000). Among the 5 initially serum CrAg-negative cases, 4 were later confirmed as proven PC via the combined method of BALF and the other one by percutaneous lung biopsy.

Conclusion

The combined method of BALF pathogen detection with BALF-CrAg showed a similar statistical efficiency rate for diagnosing pulmonary cryptococcosis compared with serum CrAg tests. It may serve as an efficient diagnosis method for PC cases with negative serum CrAg tests.

Для цитирования: Yan Q F, Sun Z L, Gao Y, Xiao T, Lin H, Ji M. [Diagnostic value of the combinations of bronchoalveolar lavage fluid pathogen detection and cryptococcal antigen test in pulmonary cryptococcosis].. Zhonghua jie he he hu xi za zhi = Zhonghua jiehe he huxi zazhi = Chinese journal of tuberculosis and respiratory diseases. 2021. DOI: 10.3760/cma.j.cn112147-20201123-01113.