MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/jaha.125.045174

Медицинская библиотека · Journal of the American Heart Association · 2026

Severe Aortic Stenosis Is Associated With Left Atrial Prothrombotic Flow That Persists Despite Valve Replacement.

Spartera Marco, Stracquadanio Antonio, Bognoni Ludovica, Tang Pok-Tin, Casadei Barbara, Wijesurendra Rohan S, Ferreira Vanessa M, Rider Oliver, Neubauer Stefan, Rigolli Marzia, Myerson Saul

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Severe aortic stenosis (AS) is associated with ischemic stroke independently of atrial fibrillation or other causes. Even after aortic valve replacement (AVR), patients remain affected by a 6% 5-year stroke rate with knowledge gaps in the underlying pathophysiology. We hypothesize that severe AS is associated with prothrombotic left atrial (LA) flow changes that do not normalize after AVR.

METHODS

Seventy-seven participants without atrial fibrillation were recruited: 40 with severe AS (median age, 73 years; CHA2DS2VASc score, 3) and 37 controls with similar risk profile (median age, 71 years; CHA2DS2VASc score, 3). All underwent baseline cardiac magnetic resonance imaging. Among the 40 patients with AS, 23 (58%) underwent AVR and repeat cardiac magnetic resonance imaging ≈6 months after surgery.

RESULTS

Compared with controls, patients with severe AS displayed significantly higher left ventricular (LV) mass (P=0.04), smaller LV volumes (P=0.01), and reduced global longitudinal strain (P<0.001). Although LA volume was within the normal range and LA emptying fraction was not different from controls, severe AS was associated with lower LA peak flow velocity (mean, 0.25 versus 0.28 m/s, respectively; P=0.02) and lower LA flow vorticity (mean, 16.6 versus 21.1 radians; P<0.001) compared with controls. AVR led to regression of LV hypertrophy with LV mass that was no longer different from controls (P=0.32). Nevertheless, post-AVR patients displayed a persistent adverse morpho-functional phenotype characterized by persistently lower velocity (mean, 0.24 versus 0.28 m/s; P=0.003) and vorticity (17.1 versus 21.1 radians; P<0.001) compared with controls.

CONCLUSIONS

Patients with severe AS display adverse prothrombotic LA flow characteristics that persist after successful AVR despite general regression of LV hypertrophy.

Для цитирования: Spartera Marco, Stracquadanio Antonio, Bognoni Ludovica, Tang Pok-Tin, Casadei Barbara, Wijesurendra Rohan S, Ferreira Vanessa M, Rider Oliver, Neubauer Stefan, Rigolli Marzia, Myerson Saul. Severe Aortic Stenosis Is Associated With Left Atrial Prothrombotic Flow That Persists Despite Valve Replacement.. Journal of the American Heart Association. 2026. DOI: 10.1161/jaha.125.045174.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.