MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/icvts/ivae182

Медицинская библиотека · Interdisciplinary cardiovascular and thoracic surgery · 2024

Feasibility, safety and quality of complex mitral valve repair in the early phase of a robotic surgery programme.

Kobayashi Kei, Guo Yizhan, Rubino Thomas E, Ramirez Luis E, Waterford Stephen D, Sultan Ibrahim, Morell Victor D, Bonatti Johannes

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the feasibility, safety and quality of robotic-assisted mitral valve repair in complex versus non-complex cases during the early phase of a programme.

METHODS

Since the programme launch in September 2021 until February 2024, 100 patients underwent robotic-assisted mitral valve repair. Of them, 21 patients had complex repairs, while 79 had non-complex repairs. The median age was 58 years for complex cases and 61 years for non-complex cases (P = 0.36).

RESULTS

Bileaflet prolapse was significantly more prevalent in the complex group (52.4% vs 12.7%, P < 0.001). Neochord placement (61.9% vs 13.9%, P < 0.001) and commissuroplasty (28.6% vs 5.1%, P = 0.005) were more frequent in the complex group. The complex group had longer cardiopulmonary bypass times (161 vs 141 min, P < 0.001), aortic cross-clamp times (123 vs 102 min, P < 0.001) and leaflet repair times (43 vs 24 min, P < 0.001). Second pump runs were required more often for complex cases (23.8% vs 3.8%, P = 0.01). All patients left the operating room with residual mitral regurgitation of mild or less. Fewer complex patients were extubated in the operating room (42.9% vs 70.9%, P = 0.02), yet hospital stay was similar (4 vs 4 days, P = 0.56). There were no significant differences in postoperative adverse events. There were no differences in mitral regurgitation of mild or less 4 weeks post-surgery (95.2% vs 98.7%, P = 0.47).

CONCLUSIONS

Complex mitral valve repair can be safely and effectively performed with robotic assistance, even in the early phase of a programme. Despite longer operative and ventilation times in the complex group, hospital stay and postoperative adverse events remained similar.

Для цитирования: Kobayashi Kei, Guo Yizhan, Rubino Thomas E, Ramirez Luis E, Waterford Stephen D, Sultan Ibrahim, Morell Victor D, Bonatti Johannes. Feasibility, safety and quality of complex mitral valve repair in the early phase of a robotic surgery programme.. Interdisciplinary cardiovascular and thoracic surgery. 2024. DOI: 10.1093/icvts/ivae182.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.