MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.125.014355

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2026

Delivery System Support Prevents Endocardial Entanglement and Delamination During Left Bundle Branch Area Pacing.

Miyazaki Yuichiro, Nakajima Hiroshi, Rimmer Mark, Hanna Peter, Hayase Justin H, Do Duc H, Shivkumar Kalyanam, Mori Shumpei

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The mechanisms behind endocardial entanglement and resultant delamination during left bundle branch area pacing, as well as potential solutions, have not been fully demonstrated in the human heart.

METHODS

Active fixation of a lumenless screw-in lead into the right ventricular septum was attempted with or without delivery system support using donor human hearts rejected for transplant. Delivery sheath support was ensured through firm catheter support maintained by a fixed clip. Endocardial entanglement, endocardial delamination after unscrewing, and lead penetration were evaluated using both macroscopic and microscopic analyses.

RESULTS

Each of 10 lead deployments with or without support was attempted using 4 donor human hearts. There was a higher incidence of endocardial entanglement and resultant helix-only penetration in the nonsupport group than the support group (70% versus 0%). Unscrewing after the endocardial entanglement consistently revealed extensively delaminated endocardium entwined around the helix. The median endocardial delamination area was larger in the entanglement group than in the nonentanglement group (25.0 mm2 versus 0.9 mm2, P<0.001). In the regions with endocardial entanglement, histological analysis confirmed extensive endocardial delamination with minimal myocardial injury. On the other hand, localized endocardial delamination and deep intramural penetration were observed in the regions without entanglement. Screw-in procedures reattempted into the regions with extensive endocardial delamination following entanglement achieved deep penetration even without delivery system support.

CONCLUSIONS

Endocardial entanglement and delamination were confirmed in donor human hearts. Adequate delivery system support, particularly its coaxiality and counterforce effect, is likely to prevent endocardial entanglement and facilitate effective penetration of a lumenless screw-in lead into the human ventricular septum.

Для цитирования: Miyazaki Yuichiro, Nakajima Hiroshi, Rimmer Mark, Hanna Peter, Hayase Justin H, Do Duc H, Shivkumar Kalyanam, Mori Shumpei. Delivery System Support Prevents Endocardial Entanglement and Delamination During Left Bundle Branch Area Pacing.. Circulation. Arrhythmia and electrophysiology. 2026. DOI: 10.1161/circep.125.014355.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.