Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2020

Subcutaneous Ports for Chronic Nerve Cuff and Intramuscular Electrode Stimulation in Animal Models.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Heaton James T, Kobler James B, Ottensmeyer Mark P, Petrillo Robert H, Tynan Monica A, Hillman Robert E, Zeitels Steven M

Аннотация

OBJECTIVE: Tracking recovery after nerve injury may require many intermittent assessments over long periods, preferably with non- or minimally invasive methods. We developed subcutaneous electrical connection ports (ECPs) for repeated connection to nerve cuff or intramuscular electrodes via transdermal needles and evaluated them during studies of laryngeal reinnervation.

STUDY DESIGN: Animal experiment.

SETTING: Laboratory.

METHODS: ECPs were designed and 3-dimensionally printed for connection to bipolar electrodes with biocompatible polymers. Dual compartments filled with conductive silicone capped with nonconductive silicone were used to make the connections between electrode leads and transdermally inserted needles. Ten dogs (19-29 kg) were implanted with 22 ECPs. In 7 dogs, 11 electrodes were placed on recurrent laryngeal nerves proximal to transection and suture repair to track laryngeal reinnervation. In 6 dogs, 8 spinal accessory nerve cuff electrodes were used to stimulate neck muscle contraction. In 2 dogs, 3 electrodes were implanted in the thyroarytenoid muscle. Stimulation thresholds, electromyography, and videolaryngoscopic imaging were obtained in 156 tests over survival periods up to 32 months. Stimulation data provided information about ECP performance.

RESULTS: ECPs added negligible resistance to electrodes (mean ± SD, 2.14 ± 0.9 Ω). Despite some electrode leads breaking distally, ECPs were reliable and well tolerated at implant sites and enabled periodic assessment of nerve and muscle function over the time course of laryngeal reinnervation. Histology showed ECP encapsulation as thin layers of connective tissue and minimal acute inflammation.

CONCLUSION: Custom ECPs are easily fabricated and cause little tissue reaction over months to years of subcutaneous implantation, facilitating long-term physiologic studies.