Аннотация

BACKGROUND

Sinusoidal obstruction syndrome (SOS) refers to liver injury caused by hematopoietic stem cell transplantation (HSCT) and anticancer drugs including oxaliplatin. Increased splenic volume (SV) on computed tomography (CT) indicates oxaliplatin-induced SOS. Similarly, ultrasonography and liver stiffness measurement (LSM) by shear-wave elastography (SWE) can help diagnose SOS after HSCT; however, their usefulness for diagnosing oxaliplatin-induced SOS remains unclear. We investigated the usefulness of the Hokkaido ultrasonography-based scoring system with 10 ultrasonographic parameters (HokUS-10) and SWE in diagnosing oxaliplatin-induced SOS early.

METHODS

In this prospective observational study, ultrasonography and SWE were performed before and at 2, 4, and 6 months after oxaliplatin-based chemotherapy. HokUS-10 was used for assessment. CT volumetry of the SV was performed in clinical practice, and an SV increase ≥ 30% was considered the diagnostic indicator of oxaliplatin-induced SOS. We assessed whether HokUS-10 and SWE can lead to an early detection of oxaliplatin-induced SOS before an increased SV on CT.

RESULTS

Of the 30 enrolled patients with gastrointestinal cancers, 12 (40.0%) with an SV increase  ≥ 30% on CT were diagnosed with SOS. The HokUS-10 score was not correlated with an SV increase ≥ 30% (r = 0.18). The change in rate of three HokUS-10 parameters were correlated with an SV increase ≥ 30% (r = 0.32-0.41). The change in rate of LSM by SWE was correlated with an SV increase  ≥ 30% (r = 0.40).

CONCLUSIONS

The usefulness of HokUS-10 score was not demonstrated; however, some HokUS-10 parameters and SWE could be useful for the early diagnosis of oxaliplatin-induced SOS.

Для цитирования: Saito Rika, Kawamoto Yasuyuki, Nishida Mutsumi, Iwai Takahito, Kikuchi Yasuka, Yokota Isao, Takagi Ryo, Yamamura Takahiro, Ito Ken, Harada Kazuaki, Yuki Satoshi, Komatsu Yoshito, Sakamoto Naoya. Usefulness of ultrasonography and elastography in diagnosing oxaliplatin-induced sinusoidal obstruction syndrome.. International journal of clinical oncology. 2022. DOI: 10.1007/s10147-022-02235-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.