m+Medelevator.RU
← Поиск публикаций
Journal of visualized experiments : JoVE · 2026

A Lip Fixation Device Facilitates Labial Salivary Gland Biopsy for Sjögren's Disease.

СтатьяVideo-Audio MediaПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Li Jia-Zhe, Feng Jun-Mei, Lan Hong, Dai Lie, Ouyang Zhi-Ming, Mo Ying-Qian

Аннотация

The protocol aims to standardize and simplify labial salivary gland biopsy (LSGB) in suspected Sjögren's disease (SjD) using a lip fixation device, enabling safe, efficient, and operator-independent procedures with reduced technical difficulty, especially for junior rheumatologists. We developed a step-by-step protocol encompassing preoperative assessment, antisepsis, local anesthesia, device-assisted lip stabilization, precise vertical incision (5-7 mm), blunt dissection, gland harvesting (minimum 4-6 glands), and standardized closure. The device consists of two clamp arms, an oval pressure ring (major axis 2.4 cm, minor axis 1.5 cm), a matching backing plate separated by a 2.1 cm gap, and a precision screw mechanism. After the patient was positioned supine on the bed, clinical inspection was performed, followed by a "go/no-go" assessment to exclude localized active infection, mucosal ulceration, significant debris, or lip masses. Triple antisepsis is performed with alcohol-free Type III povidone-iodine. Local infiltration anesthesia is administered away from the incision site. The lip is everted and stabilized by the device; a vertical incision is made parallel to the pressure ring axis, penetrating the epithelium while avoiding deep glands or muscle. Glands are identified as pale-yellow translucent spherules (1-2 mm) and harvested by blunt dissection. Closure is achieved with a single interrupted suture, and hemostasis is verified. The protocol enables solo performance, reduces procedure time compared with conventional methods (8.72 ± 1.88 min vs. 18.11 ± 2.65 min, p < 0.001), yields comparable complication rates between groups (all p > 0.05), and ensures acquisition of adequate tissue (>8 mm², focus score assessment feasible). The device's elastic compression prevents tissue injury despite secure stabilization, and predefined troubleshooting steps manage bleeding or suboptimal yield. This protocol standardizes LSGB with a fixation device, overcoming manual retraction challenges, reducing reliance on assistants, and supporting training and quality assurance in rheumatology, while maintaining diagnostic accuracy and patient safety.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты