Clinical Trial: Safety and Efficacy of a Novel Oesophageal Delivery System for Topical Corticosteroids Versus Placebo in the Treatment of Eosinophilic Oesophagitis.

СтатьяРандомизированное исследованиеКлиническое исследование II фазыМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lucendo Alfredo J, Nantes-Castillejo Óscar, Straumann Alex, Biedermann Luc, Bredenoord Albert J, Guagnozzi Danila, Blas-Jhon Leonardo, Wiechowska-Kozlowska Anna, Weidlich Simon, von Arnim Ulrike, Santander-Vaquero Cecilio, Perelló Antonia, Pérez-Martínez Isabel, Barrio Jesús, Vieth Michael, Gouya Ghazaleh, Dellon Evan S

Аннотация

BACKGROUND: EsoCap is a thin mucoadhesive film designed to target the oesophageal mucosa. The device loaded with mometasone furoate (ESO-101) is under investigation for the treatment of eosinophilic oesophagitis (EoE).

AIMS: To evaluate the efficacy, safety and tolerability of ESO-101 in patients with active EoE.

METHODS: We conducted a randomised, placebo-controlled, phase 2, proof-of-concept trial at 14 European sites in adults with EoE. Participants received placebo, uncoated EsoCap (n = 15), or EsoCap loaded with 800 μg of mometasone furoate (n = 28) once daily during 28 days. The primary outcome was the absolute change in the peak eosinophil count; secondary outcomes were histologic, clinical and endoscopic measures.

RESULTS: Treatment with ESO-101 resulted in reduction (mean ± SD) of 49.1 ± 88.4 eosinophils/high-power field from baseline, compared with 6.6 ± 65.1 with placebo (p = 0.03). With ESO-101, 48% and 44% of patients achieved < 15 and < 6 eosinophils/high-power field, respectively; these were 0% with placebo. EoE Endoscopic Reference Score reduced significantly in patients treated with ESO-101. In contrast, dysphagia and odynophagia severity decreased similarly in both groups. There were no serious treatment-emergent adverse events. Mean serum cortisol did not change significantly throughout the trial. Notably, no oropharyngeal or oesophageal candidiasis was documented. The device was well tolerated.

CONCLUSIONS: ESO-101 was superior to placebo in reducing oesophageal eosinophilia. The device was safe and well tolerated in adults with EoE, supporting the continued development of ESO-101 for the treatment of EoE (Trials.gov No.: NCT04849390; Eu-CT No.: 2020-000082-16).