MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/cancers18061009

Медицинская библиотека · Cancers · 2026

Initial Evaluation of Feasibility and Cutaneous Toxicity of Electron FLASH Radiotherapy Using a Standard-of-Care Fractionation Scheme in a Porcine Skin Model.

Konradsson Elise, Liu Kevin, Baig Safee, Lin Susanne Je-Han, Lopez Alan Hernandez, Velasquez Brett, Mayor Stephanie, Samuel Kayla, Viscarra Traci, Garrow Krystal, Moore Erica J, Norton William, Swain Jody, Li Ziyi, Koong Albert C, Lin Steven H, Schüler Emil, Mitra Devarati

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

FLASH radiotherapy (RT) has shown potential to reduce normal tissue toxicity compared with conventional (CONV) RT while maintaining tumor control. FLASH RT is characterized by ultra-high dose rate delivery, commonly using mean dose rates ≥ 40 Gy/s and sub-second delivery times. Most preclinical studies have used single-fraction regimens, leaving the feasibility and normal tissue impact of clinically relevant fractionation largely unexplored. We evaluated electron FLASH RT given in a standard five-fraction regimen to a porcine skin model, simulating adjuvant treatment workflow for high-risk cutaneous melanoma. Method: Three Yorkshire-Landrace swine received paired five-fraction electron irradiations to dorsolateral skin using either FLASH RT (mean dose rates 175-246 Gy/s) or CONV RT (8 Gy/min). Radiation was delivered with a 9-MeV electron beam; field diameters of 4, 7, or 10 cm; and doses of 5 × 6, 5 × 7, or 5 × 8 Gy. Dosimetry was validated with several dosimeters and real-time beam monitoring, confirming dose accuracy within 3%. Skin toxicity was assessed over 22-24 weeks using clinical grading, erythema spectrophotometry, and histopathologic evaluation.

Results

FLASH RT was well tolerated at 5 × 6 Gy and 5 × 7 Gy, with no significant differences in peak radiation dermatitis, erythema index, or histologic damage compared with CONV RT. At 5 × 8 Gy, both modalities caused unacceptable toxicity, including moist desquamation and necrosis. No volume-dependent effects were observed.

Conclusions

Although a FLASH-specific normal tissue sparing effect was not observed, this study demonstrates the technical feasibility and safety of delivering fractionated electron FLASH RT in a large animal model using a clinically relevant workflow. These findings support further investigation of physical beam parameters and biological modifiers, such as tissue oxygenation, and inform the clinical translation of fractionated FLASH RT for cutaneous malignancies.

Для цитирования: Konradsson Elise, Liu Kevin, Baig Safee, Lin Susanne Je-Han, Lopez Alan Hernandez, Velasquez Brett, Mayor Stephanie, Samuel Kayla, Viscarra Traci, Garrow Krystal, Moore Erica J, Norton William, Swain Jody, Li Ziyi, Koong Albert C, Lin Steven H, Schüler Emil, Mitra Devarati. Initial Evaluation of Feasibility and Cutaneous Toxicity of Electron FLASH Radiotherapy Using a Standard-of-Care Fractionation Scheme in a Porcine Skin Model.. Cancers. 2026. DOI: 10.3390/cancers18061009.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.