DOI 10.1016/j.jtos.2017.10.005
Randomized double-masked trial of eyelid cleansing treatments for blepharitis.
Аннотация
PURPOSE: To compare the efficacy of a dedicated eyelid cleanser and diluted baby shampoo in the management of blepharitis.
METHODS
Forty-three participants with clinical blepharitis signs were enrolled in a prospective, randomized, double-masked, paired-eye trial. A dedicated eyelid cleanser (TheraTears® SteriLid®) was applied to the eyelids of one eye (randomized) and diluted baby shampoo (Johnson's® No More Tears®) to the fellow eye, twice daily for 4 weeks. Tear film parameters, ocular surface characteristics, symptomology and cytology markers were assessed at baseline and day 28.
RESULTS
Baseline measurements did not differ between treatments (all p > 0.05). The eyelid cleanser was preferred over baby shampoo by the majority of participants (p < 0.001). Improvements in the tear lipid layer, inferior lid wiper epitheliopathy (LWE), cylindrical collarettes, and MMP-9 expression were limited to the dedicated eyelid cleanser (all p < 0.05), and a greater decrease in SANDE symptoms score was also observed (p = 0.04). Meibomian gland capping and MUC5AC expression worsened with baby shampoo treatment (both p < 0.05). SPEED symptoms score, superior LWE, seborrhoeic lash crusting, and trichiasis decreased significantly following application of both treatments (all p < 0.05), but did not differ between treatments (all p > 0.05).
CONCLUSION
Clinical improvements in blepharitis occurred with both treatments. However, only the dedicated eyelid cleanser proved effective in reducing ocular surface inflammation, and was the preferred therapy. Long term impact of decreased goblet cell function secondary to baby shampoo treatment requires further exploration.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.