MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ohn.70304

Медицинская библиотека · Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2026

Is COVID-19 Infection A Risk Factor for Intubation-Related Acquired Airway Stenosis?

Taylor Kristell M, Tang Jessica A, Amadio Grace, Ni Garrett, Dass Chandra, Soliman Ahmed M S

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine whether COVID-19 is a risk factor for developing airway stenosis in intubated patients.

STUDY

DESIGN

Retrospective case-control study with planned chart review.

SETTING

Temple University Health Systems hospitals in Philadelphia, PA.

METHODS

Chart review of patients 18 to 90 years old diagnosed with COVID-19 who underwent endotracheal intubation and had a post-extubation CT scan at our institution between February 2020 and December 2022 was performed. Patients without COVID-19 matched for age, sex, and BMI who were intubated within one year served as a control group. Outcome variables included endoscopic and radiographic evidence of airway stenosis. Descriptive statistics were analyzed using Chi-squared and unpaired two-tailed T-test analyses for cohort comparison.

RESULTS

One hundred five COVID-positive and 101 COVID-negative met inclusion criteria. The mean age was 58.6 years. Mean endotracheal tube size was 8.05 for COVID-positive and 7.72 for COVID-negative patients (P = .0075). Twenty-six (24.76%) COVID-positive and 45 (44.55%) COVID-negative patients had COPD (P = .0016). Length of intubation was 8.8 days in COVID-positive patients and 3.5 days for COVID-negative patients (P < .0001). Thirty-five (33.98%) COVID-positive and 1 (0.99%) COVID-negative patient were ventilated while prone (P = .0002). Seventy-eight (75%) COVID-positive and 38 (41.76%) COVID-negative patients received intravenous steroids (P = .0001). Mean length of stay was 38.81 days for COVID-positive and 17.16 days for COVID-negative patients (P < .0004). Six (5.77%) COVID-positive and 2 (1.3%) COVID-negative patients developed airway stenosis (P = .202).

CONCLUSION

Patients with COVID-19 infection were not at an increased risk for intubation-related airway stenosis.

LEVEL OF EVIDENCE: IV.

Для цитирования: Taylor Kristell M, Tang Jessica A, Amadio Grace, Ni Garrett, Dass Chandra, Soliman Ahmed M S. Is COVID-19 Infection A Risk Factor for Intubation-Related Acquired Airway Stenosis?. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2026. DOI: 10.1002/ohn.70304.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.