m+Medelevator.RU
← Поиск публикаций
Journal of neurointerventional surgery · 2025

Carotid web catheter angiography hemodynamic parameters.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Damiani Monteiro Mateus, Tarek Mohamed A, Martins Pedro N, Allen Jason W, Nogueira Raul G, Landzberg David, Dolia Jaydevsinh, Park Charlie Chulhyun, Liberato Bernardo, Frankel Michael R, Haussen Diogo C

Аннотация

BACKGROUND: Carotid web (CaW)-related contrast stagnation on digital subtraction angiography (DSA) may be a marker supporting the pathophysiological theory of stasis and thrombosis/embolization. We aim to assess the correlation between DSA hemodynamic parameters with CT angiography (CTA) structural measurements and clinical characteristics.

METHODS: Cross-sectional analysis of consecutive patients with CaW who underwent CTA+DSA. DSA-derived hemodynamic parameters were calculated based on a region of interest at the carotid bulb (time-density curves; TDC). The correlation between duration of contrast stagnation with CaW structural features and with clinical characteristics was evaluated with a mixed effects model.

RESULTS: Sixty patients of mean±SD age 52.2±10.3 years were included, of whom 38 (63.3%) were women, 51 (85%) were black, and 59 (98.3%) had symptomatic lesions. The median CaW base was 2.46 mm (range 1.95-3.76), length 2.7 mm (range 2.15-3.96), thickness (length/base) 1.05 (IQR 0.81-1.36), caudal angle 31.93° (IQR 22.35-43.58), mean±SD distal angle 66.91±15.84°, pocket area 1.62 mm² (0.96-1.62), and pocket perimeter 6.03±2.6 mm. The TDC consistently showed an initial fast decay from the peak concentration followed by a plateau with a negative exponential pattern. The median stagnation time from peak density to 80% contrast clearance was 2.91 s (range 1.81-4.94). No significant associations were observed between the stagnation time and CaW CTA structural measurements (length/base/thickness, caudal and cranial angles web surface angles, web pocket area/perimeter) or clinical characteristics.

CONCLUSIONS: A negative exponential pattern in the DSA contrast clearance of the CaW pocket was observed. There were no morphological or clinical features clearly associated with the duration of contrast stagnation on DSA. The hemodynamic disruption caused by CaW and its thrombotic risk may not be appropriately measured by contrast stagnation time.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты