m+Medelevator.RU
← Поиск публикаций
International ophthalmology · 2026

Comparison of functional outcomes between femtosecond laser-assisted cataract surgery and phacoemulsification in post-radial keratotomy cataract.

СтатьяСравнительное исследованиеНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Parihar Jitendra Kumar Singh, Sachdev Mahipal Singh, Dhar Suhani, Sharma Meenakshi, Parihar Ashwini Kumar Singh

Аннотация

PURPOSE: To compare the functional outcomes between femtosecond laser-assisted cataract surgery (FLACS) and phacoemulsification in post-radial keratotomy (RK) cataract.

SETTING: Postgraduate teaching institute in a corporate setting, based in Northern India.

DESIGN: Retrospective comparative observational study.

METHODS: The study included 70 post-RK eyes that underwent cataract surgery by FLACS in 38 eyes and by phacoemulsification in the remaining 32 eyes over the past 5 years, with nuclear cataract grades II-IV. Preoperative astigmatism ranged from ± 0.50 to 5.50 D in both groups and was managed with Toric IOL implantation. Barrett True-K and SRK/T were used to calculate IOL power. Follow-up ranged from 1 to 4 years.

RESULTS: Incomplete Rhexis, Inadequate Nucleotomy, and wound dehiscence were noted constraints in both groups. The mean postoperative uncorrected visual acuity (LogMAR) was 0.23 ± 0.09 in the PHACO group (n = 32), 0.22 ± 0.06 in the FLACS group (n = 38), and 0.22 ± 0.08 in the combined group, with a P value of 0.885. Residual astigmatism or spherical error ranged from plus or minus 0.75 to 3.25 dioptres. The FLACS group had a higher mean astigmatism correction (1D) than the phacoemulsification group (0.25D), attributable to precision in incision, rhexis, Nucleotomy, and rotational stability of the Toric IOL implant.

CONCLUSIONS: The Barrett True-K formula provided better predictive accuracy for the presumed IOL power than SRK/T in these cases. Both groups showed statistically significant improvement after FLACS or phacoemulsification, with slightly better outcomes after FLACS with laser energy modulation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты