MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jaad.2016.08.024

Медицинская библиотека · Journal of the American Academy of Dermatology · 2016

Validation of diagnostic accuracy with whole-slide imaging compared with glass slide review in dermatopathology.

Shah Kabeer K, Lehman Julia S, Gibson Lawrence E, Lohse Christine M, Comfere Nneka I, Wieland Carilyn N

Сравнительное исследованиеСтатьяВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Teledermatopathology has evolved from static images to whole slide imaging (WSI), which allows for remote viewing and manipulation of tissue sections. Previous studies of WSI in teledermatopathology predated College of American Pathologists (CAP) telepathology validation guidelines.

OBJECTIVE

We conducted a comprehensive retrospective WSI validation study of routine dermatopathology cases, adhering to CAP guidelines.

METHOD: In all, 181 consecutive cases arranged into 3 categories (inflammatory, melanocytic, nonmelanocytic proliferations) were reviewed by 3 board-certified dermatopathologists via traditional microscopy (TM) and WSI. Intraobserver (TM vs WSI), TM intraobserver and interobserver (TM vs TM), and WSI interobserver (WSI vs WSI) concordance was interpreted using a 3-tier system.

RESULTS

TM versus WSI intraobserver concordance (86.9%; 95% confidence interval [CI] 83.7-89.6) did not differ from TM versus TM intraobserver concordance (90.3%; 95% CI 86.7-93.1) or interobserver concordance (WSI: 89.9%; 95% CI 87.0-92.2, and TM: 89.5%; 95% CI 86.5-91.9). Melanocytic proliferations had the lowest TM versus WSI intraobserver concordance (75.6%; 95% CI 68.5-81.5), whereas inflammatory lesions had the highest TM versus WSI intraobserver concordance (96.1%; 95% CI 91.8-98.3). Nonmelanocytic proliferations had an intraobserver concordance of 89.1% (95% CI 83.4-93.0).

LIMITATIONS: Efficiency and other logistical WSI parameters were not evaluated.

CONCLUSION

Intraobserver and interobserver diagnostic concordance between WSI and TM was equivalent. Therefore, WSI appears to be a reliable diagnostic modality for dermatopathology.

Для цитирования: Shah Kabeer K, Lehman Julia S, Gibson Lawrence E, Lohse Christine M, Comfere Nneka I, Wieland Carilyn N. Validation of diagnostic accuracy with whole-slide imaging compared with glass slide review in dermatopathology.. Journal of the American Academy of Dermatology. 2016. DOI: 10.1016/j.jaad.2016.08.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.