Sutureless intrascleral intraocular lens implantation after ocular trauma.

Saleh Maher, Heitz Antoine, Bourcier Tristan, Speeg Claude, Delbosc Bernard, Montard Michel, Gaucher David

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To report the results and safety of sutureless intrascleral haptic fixation in traumatized eyes and to compare this procedure with retropupillary iris-claw intraocular lens (IOL) fixation.

SETTING

University Hospital of Strasbourg, Strasbourg, France.

DESIGN

Interventional case series.

METHODS

Patients with traumatic cataract and severely damaged capsular bags were divided into 2 groups (Group 1: intrascleral IOLs [Acrysof MN60 AC]; Group 2: retropupillary iris-claw IOLs [Verisyse]). The main outcome was the final visual acuity. The surgically induced astigmatism (SIA) was calculated by the vectorial method.

RESULTS

Twenty-six eyes of 23 patients were studied, 8 eyes in Group 1 and 18 eyes in Group 2. The mean follow-up was 14 months. There was no difference in corrected distance visual acuity (CDVA) at the time of the surgery (P>.05). The mean CDVA (logMAR) was 1.68 ± 1.15 (SD) preoperatively and 0.55 ± 0.9 postoperatively in Group 1 (P = .03) and 1.11 ± 1.13 and 0.32 ± 0.47, respectively, in Group 2 (P = .003). The final CDVA was not different between groups (P>.05). The mean SIA was 1.91 ± 1.66 diopters (D) in Group 1 and 2.74 ± 1.92 D in Group 2 (P>.05). No intraoperative complications occurred in Group 2; a haptic broke in Group 1. Macular edema occurred in both groups.

CONCLUSIONS

Sutureless intrascleral IOLs corrected posttraumatic aphakia. The SIA was comparable between groups. This procedure should be considered after trauma when other implantation techniques are not possible.

Для цитирования: Saleh Maher, Heitz Antoine, Bourcier Tristan, Speeg Claude, Delbosc Bernard, Montard Michel, Gaucher David. Sutureless intrascleral intraocular lens implantation after ocular trauma.. Journal of cataract and refractive surgery. 2013. DOI: 10.1016/j.jcrs.2012.08.063.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.