Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2026

Real-World Study Assessing the Efficacy and Safety of a Novel KLEx Procedure with a Next-Generation Femtosecond Laser for Refractive Error Correction.

Ozkan Jerome, Shroff Rushad, Arora Ritu, Agrawal Apoorva, Gupta Palak, Chiang Vivien, Schwam Brian L

СтатьяПеревод в очереди

Аннотация

PURPOSE: ELITA Femtosecond Laser System (Johnson & Johnson) is a next-generation ophthalmic laser platform designed for Smooth Incision Lenticular Keratomileusis (SILK). A retrospective study evaluated refractive outcomes, visual acuity, higher-order aberrations (HOAs), tear film parameters, and dry eye symptoms 30 days postoperatively.

PATIENTS AND

METHODS

A retrospective, non-comparative, case series analyzing real-world data from patients with myopia treated using the SILK procedure with the ELITA femtosecond laser. The study included 144 eyes from 73 consecutive patients (47 female, 26 male) with myopia (-4.51 ± 1.36 D; range -1.50 D to -8.250 D). Refraction and uncorrected distance visual acuity (UDVA) were assessed preoperatively and at 1, 7, and 30 days postoperatively. A subset of 18 patients (36 eyes) underwent additional evaluation of tear film (Keratograph, LipiView, Schirmer II, NIBUT), dry eye symptoms (OSDI), and HOAs/contrast sensitivity (iTrace).

RESULTS

At 30-days, 96.5% of eyes (139/144) achieved 20/20 UDVA while the remaining 3.5% achieved 20/25. The mean spherical equivalent was -0.22 ± 0.68 D. No significant changes were observed in tear film metrics, HOAs, or contrast sensitivity. A statistically significant difference in vertical coma was noted (0.05 ± 0.04 µm vs 0.1 ± 0.09 µm, P = 0.008), though not clinically relevant. No serious adverse events occurred.

CONCLUSION

The SILK procedure with the ELITA femtosecond laser platform is safe and effective for myopia correction (with and without astigmatism), with no detrimental effect on tear film stability, dry eye symptoms, or visual quality at 30 days post-surgery.

Для цитирования: Ozkan Jerome, Shroff Rushad, Arora Ritu, Agrawal Apoorva, Gupta Palak, Chiang Vivien, Schwam Brian L. Real-World Study Assessing the Efficacy and Safety of a Novel KLEx Procedure with a Next-Generation Femtosecond Laser for Refractive Error Correction.. Clinical ophthalmology (Auckland, N.Z.). 2026. DOI: 10.2147/opth.s580385.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.