MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-017-18915-5

Медицинская библиотека · Scientific reports · 2018

Speciation of common Gram-negative pathogens using a highly multiplexed high resolution melt curve assay.

Edwards Thomas, Sasaki Shugo, Williams Christopher, Hobbs Glyn, Feasey Nicholas A, Evans Katie, Adams Emily R

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The identification of the bacterial species responsible for an infection remains an important step for the selection of antimicrobial therapy. Gram-negative bacteria are an important source of hospital and community acquired infections and frequently antimicrobial resistant. Speciation of bacteria is typically carried out by biochemical profiling of organisms isolated from clinical specimens, which is time consuming and delays the initiation of tailored treatment. Whilst molecular methods such as PCR have been used, they often struggle with the challenge of detecting and discriminating a wide range of targets. High resolution melt analysis is an end-point qPCR detection method that provides greater multiplexing capability than probe based methods. Here we report the design of a high resolution melt analysis assay for the identification of six common Gram-negative pathogens; Escherichia coli, Klebsiella pneumoniae, Klebsiella oxytoca, Pseudomonas aeruginosa, Salmonella Sp, and Acinetobacter baumannii, and a generic Gram-negative specific 16S rRNA control. The assay was evaluated using a well characterised collection of 113 clinically isolated Gram-negative bacteria. The agreement between the HRM assay and the reference test of PCR and sequencing was 98.2% (Kappa 0.96); the overall sensitivity and specificity of the assay was 97.1% (95% CI: 90.1-99.7%) and 100% (95% CI: 91.78-100%) respectively.

Для цитирования: Edwards Thomas, Sasaki Shugo, Williams Christopher, Hobbs Glyn, Feasey Nicholas A, Evans Katie, Adams Emily R. Speciation of common Gram-negative pathogens using a highly multiplexed high resolution melt curve assay.. Scientific reports. 2018. DOI: 10.1038/s41598-017-18915-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.