Ocular biometry agreement among ZW-30, IOLMaster 700, and sirius in cataract patients.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yang Junjie, Yang Nijuan, Xiang Yuying, Li Rui, Yu Xuan, Jin Ling, Huang Yukan

Аннотация

Accurate ocular biometry is crucial for the success of refractive cataract surgery. This study aims to assess the consistency and differences of a new biometer, the ZW-30, compared with the mainstream devices IOLMaster 700 and Sirius in patients with cataracts. A total of 307 patients with cataracts (603 eyes) were included. The anterior chamber depth (ACD), central corneal thickness (CCT), white-to-white (WTW) distance, pupil diameter (PD), flat K (K1), steep K (K2), corneal astigmatism (ΔK), total keratometry (TK), total corneal astigmatism (TCA), astigmatism axis, kappa angle (κ), axial length (AL), and lens thickness (LT) were measured using the ZW-30, IOLMaster 700, and Sirius. The consistency between devices was evaluated using Bland-Altman analysis, the correlation of parameters was assessed using Spearman correlation analysis, and inter-device agreement equations were established. Strong correlations (r ≥ 0.7) and no statistically significant differences in mean values (p > 0.05) were found for ACD, CCT, AL, LT, and anterior corneal curvature (K1/K2) among the three devices, but the 95% limits of agreement (LoA) exceeded the clinical threshold. Total corneal parameters (TK/TCA) and κ angle showed strong correlations (r ≥ 0.5) among the three devices, with significant inter-device differences in mean values (p < 0.05) and 95%LoA exceeding the clinical threshold. Corneal diameter (WTW) had a weak correlation (r = 0.48) between the ZW-30 and Sirius, and differences in PD measurement methods led to systematic bias. The ZW-30 is consistent with the IOLMaster 700 and Sirius in terms of group trends for basic biometric parameters (ACD/CCT/anterior corneal curvature), but significant individual differences exist (95%LoA exceeding the threshold). Total corneal parameters (TK/TCA) and κ angle require cross-validation with Sirius. WTW and PD are not interchangeable between devices due to differences in measurement principles. Cross-device parameter conversion should be avoided in clinical practice to ensure the accuracy of refractive surgery.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты