MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.abd.2025.501126

Медицинская библиотека · Anais brasileiros de dermatologia · 2025

Prevalence of reactive allergens in contact patch testing studies using the Brazilian standard battery: a systematic review.

Bueno Ana Laura Andrade, Aguzzoli Nathalia Hoffmann Guarda, Bonamigo Renan Rangel

СтатьяСистематический обзорПеревод в очереди

Аннотация

BACKGROUND

Contact dermatitis is a common dermatosis in dermatology. The patch test is the gold standard for diagnosis, using a panel of common allergens and irritants. In Brazil, a standardized battery of 30 substances is used. However, comprehensive epidemiological data on contact dermatitis are limited, and no studies have compiled and compared nationwide results.

OBJECTIVES

This study aimed to assess the positivity rate of patch tests using the Brazilian Standard Battery in suspected contact dermatitis cases from 2000 to 2022. We also evaluated associations between reactive substances and clinical and demographic variables and examined the variation in reactivity frequency to allergenic substances over the study period.

METHODS

A systematic literature review was conducted using PubMed, Scielo, and LILACS. We evaluated the prevalence of positive tests for each substance, examined associations between variables such as gender, region, and age, and assessed variations in patch test positivity over time.

RESULTS

Initially, 55 articles were identified, and 10 were included in the review. Nickel sulfate was the most frequently positive allergen, while triclosan, P-tertiary buthyphenol, and anthraquinone were the least prevalent. Test positivity increased every 5-years for kathon CG, neomycin, and nickel sulfate, while it decreased for quaternion 15 and thimerosal.

STUDY LIMITATIONS: The results were limited by the small number of articles included in the review.

CONCLUSIONS

This pioneering study in Brazil provides valuable insights for dermatological allergy practitioners into the prevalence of patch test positivity for each substance in the Brazilian Standard Battery, aiding in informed decision-making and patient management.

Для цитирования: Bueno Ana Laura Andrade, Aguzzoli Nathalia Hoffmann Guarda, Bonamigo Renan Rangel. Prevalence of reactive allergens in contact patch testing studies using the Brazilian standard battery: a systematic review.. Anais brasileiros de dermatologia. 2025. DOI: 10.1016/j.abd.2025.501126.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.