The Structure-Function Link of Ellipsoid Zone Integrity and Outer Retinal Features with Visual Acuity in Dry AMD.

Amine Reem, Mizuno Masaharu, Matar Karen, Indurkar Asmita, Simoes Paulo, Hu Ming, Downes Rachel A, Talcott Katherine E, Reese Jamie L, Ehlers Justis P

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

The purpose of this study was to evaluate associations between quantitative ellipsoid zone (EZ) integrity metrics derived from spectral-domain OCT (SD-OCT) and visual outcomes, including clinically meaningful visual acuity (VA) loss, in dry age-related macular degeneration (AMD).

Methods

This single-center retrospective image-analysis cohort included 351 eyes from 351 patients with intermediate AMD or atrophic changes. Macular SD-OCT scans were analyzed using a certified-reader-validated machine learning-based segmentation platform to delineate the EZ, retinal pigment epithelium (RPE), and Bruch's membrane (BM). EZ metrics included EZ-RPE thickness (i.e., outer segment thickness) and EZ attenuation, defined as partial attenuation (EZ-RPE thickness of ≤20 µm, abnormal outer segment thinning)) or total attenuation/loss (0 µm). Drusen volume was quantified from the RPE-BM compartment. VA was converted to ETDRS letters. Associations between baseline OCT metrics and baseline VA, Year 2 VA, and ≥15-letter VA loss were assessed using nonparametric testing, linear regression, and ANCOVA.

Results

Greater EZ-RPE thickness and lower EZ attenuation were associated with better baseline VA (all p < 0.001), and EZ metrics remained significant in cross-sectional regression models. Among 188 eyes with Year 2 follow-up, 38 (20%) experienced ≥15-letter VA loss. These eyes had significantly lower baseline EZ-RPE thickness (i.e., abnormal outer segment thinning) and greater EZ attenuation than eyes without such loss (all p < 0.001). In ANCOVA models, EZ metrics remained associated with Year 2 VA (all p < 0.001), whereas drusen volume was not.

Conclusions

Quantitative EZ integrity metrics were associated with cross-sectional and longitudinal visual outcomes in dry AMD. EZ-RPE thickness and EZ attenuation may serve as clinically relevant OCT biomarkers reflecting photoreceptor integrity and risk of meaningful VA loss.

Для цитирования: Amine Reem, Mizuno Masaharu, Matar Karen, Indurkar Asmita, Simoes Paulo, Hu Ming, Downes Rachel A, Talcott Katherine E, Reese Jamie L, Ehlers Justis P. The Structure-Function Link of Ellipsoid Zone Integrity and Outer Retinal Features with Visual Acuity in Dry AMD.. Diagnostics (Basel, Switzerland). 2026. DOI: 10.3390/diagnostics16182925.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.