PloS one · 2024
Subjective perception of visual field defects using random noise-moving images in patients with glaucoma: A comparison of computer graphics and analog noises.
СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Inoue Arata, Koike Eiko, Maeda Naoyuki, Matsumoto Chota
Аннотация
PURPOSE: Random noise-moving images (noises) can make glaucoma patients with no subjective symptoms aware of visual field abnormalities. To explore this concept, we developed a noise using computer graphics (CG) and investigated the difference in the subjective perception of visual field abnormalities between CG and conventional analog noises.
METHODS: We enrolled individuals with glaucoma (205 eyes), preperimetric glaucoma (PPG; 19 eyes), and normal eyes (35 eyes). For a CG noise, a series of still images was made by randomly selecting five monochromatic tones on 2-mm square dots, and these images were drawn at 60 frames per second (fps) to create a noise-moving image. The participants were asked to describe their perceived shadows on a paper. The results were categorized as follows based on the pattern deviation probability map of the Humphrey field analyzer (HFA): "agreement," "partial agreement," "disagreement," and "no response." The glaucoma stage was classified into four stages, from M1 to M4, based on the HFA's mean deviation.
RESULT: The detection rates (agreement and partial agreement) were 80.5% and 65.4% for the CG and analog noises, respectively, with CG noise showing a significantly higher detection rate in all glaucoma eyes (P < 0.001). The detection rates tended to increase as the glaucoma stage progressed, and in Stage M3, these were 93.9% and 78.8% for the CG and analog noises, respectively. The PPG eyes did not exhibit subjective abnormalities for both noises. The specificity values were 97.1% and 100% for the CG and analog noises, respectively.
CONCLUSION: The CG noise is more effective than the analog noise in evaluating the subjective perception of visual field abnormalities in patients with glaucoma.
METHODS: We enrolled individuals with glaucoma (205 eyes), preperimetric glaucoma (PPG; 19 eyes), and normal eyes (35 eyes). For a CG noise, a series of still images was made by randomly selecting five monochromatic tones on 2-mm square dots, and these images were drawn at 60 frames per second (fps) to create a noise-moving image. The participants were asked to describe their perceived shadows on a paper. The results were categorized as follows based on the pattern deviation probability map of the Humphrey field analyzer (HFA): "agreement," "partial agreement," "disagreement," and "no response." The glaucoma stage was classified into four stages, from M1 to M4, based on the HFA's mean deviation.
RESULT: The detection rates (agreement and partial agreement) were 80.5% and 65.4% for the CG and analog noises, respectively, with CG noise showing a significantly higher detection rate in all glaucoma eyes (P < 0.001). The detection rates tended to increase as the glaucoma stage progressed, and in Stage M3, these were 93.9% and 78.8% for the CG and analog noises, respectively. The PPG eyes did not exhibit subjective abnormalities for both noises. The specificity values were 97.1% and 100% for the CG and analog noises, respectively.
CONCLUSION: The CG noise is more effective than the analog noise in evaluating the subjective perception of visual field abnormalities in patients with glaucoma.