MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.heliyon.2024.e30721

Медицинская библиотека · Heliyon · 2024

Association between primary angle closure glaucoma and uric acid levels in serum and aqueous humor.

Liu Wei, Guo Ruru, Gao Fei, Huang Dandan, Zhang Xinyi, Ji Jian, Jansonius Nomdo M

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate abnormalities in serum and aqueous humor uric acid (UA) levels in primary angle closure glaucoma (PACG).

METHODS

Patients with PACG and age-similar and gender-similar controls (patients scheduled for cataract extraction) were enrolled prospectively. Serum UA levels were determined by enzymatic colorimetry; aqueous humor UA levels by Enzyme-Linked ImmunoSorbent Assay. A t-test was used to compare UA levels between PACG patients and controls, with one-way ANOVA used to compare levels across PACG subgroups with differing disease severity. Comparisons between PACG patients and controls were adjusted for systemic and ocular confounding factors using binary logistic regression.

RESULTS

In all, 131 PACG patients and 112 controls were included. The serum UA level was 266 ± 69 μmol/L in the PACG group and 269 ± 73 μmol/L in the control group (p = 0.71). The aqueous humor UA level was 35.4 ± 8.2 μmol/L in the PACG group and 53.9 ± 18.6 μmol/L in the control group (p < 0.001). This difference remained significant after adjusting for age, gender, systolic blood pressure, diastolic blood pressure, body mass index, axial length, central corneal thickness, anterior chamber depth, lens thickness, white-to-white distance, corneal endothelial cell density, and serum UA level (odds ratio: 0.88, 95 % confidence interval: 0.83-0.93, p < 0.001).

CONCLUSION

Aqueous humor UA levels differ between PACG patients and controls, but serum UA levels do not. This indicates that local UA plays a role in the pathogenesis of PACG, but systemic UA does not.

Для цитирования: Liu Wei, Guo Ruru, Gao Fei, Huang Dandan, Zhang Xinyi, Ji Jian, Jansonius Nomdo M. Association between primary angle closure glaucoma and uric acid levels in serum and aqueous humor.. Heliyon. 2024. DOI: 10.1016/j.heliyon.2024.e30721.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.