Limbal reconstruction in uveitic glaucoma patient with exposed Ahmed valve coincident with corneal melting and iris prolapse using multiple corneoscleral allografts.
Аннотация
Aim: To present a complex case of Ahmed tube exposure 6 months after the implantation associated with corneal melting and iris prolapse, and the surgical reposition that required multiple allografts and limbal reconstruction.
Methods
A 60-year-old patient arrived at the emergency room with tube exposure combined with corneal melting and iris prolapse from a previously placed Ahmed valve 6 months prior. Our approach was to use one corneoscleral graft to repair the melted cornea and avoid further iris prolapse and a second scleral graft to cover the repositioned tube. Upon completion of conjunctival dissection, cleaning and deepithelization of the melted cornea and the tube by application of alcohol 100% followed. A new entry point was made for the tube and was covered using an alcohol-preserved scleral allograft and the previous entry point was repaired using a corneoscleral allograft with the corneal aspect restoring the limbus and avoiding further iris protrusion.
Results
6 months follow-up of the patient showed excellent recovery, anatomical restoration, and IOP normalization.
Conclusion
Surgical repair of these cases can be very demanding, and requires surgical improvisation and prolonged surgical time. The literature remains very limited on how a surgeon should approach similar cases, which are the crucial tips, and which are the missteps that should be avoided. In this case, we used multiple scleral/corneoscleral allografts in a specific orientation and different sutures to reconstruct the damaged limbal area and restore the anatomy. Abbreviations: VA = Visual Acuity, GDD = Glaucoma Drainage Device, IOP = Intra Ocular Pressure.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.