MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7759/cureus.111686

Медицинская библиотека · Cureus · 2026

Deep Learning-Based CT Segmentation of a Non-radiopaque Hydrogel Rectal Spacer in Prostate Radiotherapy.

Miura Hideharu, Ozawa Shuichi, Kenjo Masahiro, Murakami Yuji

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

The study evaluated the feasibility and geometric accuracy of CT-based automatic segmentation of a non-radiopaque hydrogel rectal spacer using a commercial deep learning platform (OncoStudio) and determined whether accurate spacer delineation can be achieved without MRI while preserving the contouring quality of adjacent organs.

METHODS

This retrospective study included 21 patients with localized prostate cancer who underwent external beam radiotherapy with a non-radiopaque hydrogel rectal spacer (SpaceOAR; Boston Scientific). CT-based automatic segmentation of the rectal spacer, prostate, rectum, and bladder was performed on the planning CT using OncoStudio (version 2.0; Oncosoft Inc.). Reference contours were manually delineated on the planning CT with reference to co-registered T2-weighted MRI. Geometric accuracy was assessed using the Dice similarity coefficient (DSC), 95th-percentile Hausdorff distance (HD₉₅), and mean surface distance (MSD).

RESULTS

The mean DSC for the rectal spacer was 0.787 ± 0.073, with a mean HD₉₅ of 4.03 ± 1.83 mm and a mean MSD of 1.18 ± 0.63 mm. The adjacent organs showed high geometric agreement, with mean DSC values of 0.876, 0.890, and 0.963 for the prostate, rectum, and bladder, respectively. No systematic over- or under-segmentation was observed, and the MSD for all structures was below 2.5 mm.

CONCLUSIONS

CT-based automatic segmentation using OncoStudio provided clinically acceptable boundary delineation of a non-radiopaque hydrogel rectal spacer without requiring MRI, while maintaining the contouring quality of the surrounding organ. These findings suggest that CT-only automatic contouring can reduce spacer-specific MRI use and associated registration uncertainty in prostate radiotherapy.

Для цитирования: Miura Hideharu, Ozawa Shuichi, Kenjo Masahiro, Murakami Yuji. Deep Learning-Based CT Segmentation of a Non-radiopaque Hydrogel Rectal Spacer in Prostate Radiotherapy.. Cureus. 2026. DOI: 10.7759/cureus.111686.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.