m+Medelevator.RU
← Поиск публикаций
Journal of gastroenterology and hepatology · 2026

Randomized Controlled Trial Evaluating the Safety, Efficacy, and Patient Comfort of a Single-Use Electronic Colonoscope.

СтатьяРандомизированное исследованиеСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tian Yuan, Rao Xiaolong, Yu Hang, Zheng Lingfeng, Wang Ao, Liu Shuangjiao, He Yan, Rong Long

Аннотация

BACKGROUND AND AIM: Although reusable colonoscopes remain the clinical gold standard, persistent microbial biofilms compromise reprocessing efficacy and increase cross-contamination risk. This study evaluated a novel single-use colonoscope compared to a conventional device across key clinical and patient-centered outcomes.

METHODS: In a single-blind randomized trial, 100 patients (aged 18-80 years) undergoing conscious sedation colonoscopy were assigned (1:1) to a single-use colonoscope (Endofresh XZING-C200B) or a conventional colonoscope (Olympus CF-H260). Primary endpoints included patient comfort (assessed via real-time grip strength dynamometry), therapeutic endoscopic mucosal resection (EMR) efficacy, adenoma detection rate (ADR), adenomas per colonoscopy (APC), and cecal intubation time.

RESULTS: Groups were demographically balanced. No significant differences were observed in patient comfort (p > 0.05), EMR outcomes (100% en bloc resection; median procedure times: 11.32 ± 4.55 vs. 11.57 ± 7.95 min, p = 0.899), diagnostic performance (ADRs: 56% vs. 60%, p = 0.685; APCs median: 1.0 vs. 1.0, p = 0.349), or cecal intubation time (7.47 ± 5.81 vs. 6.13 ± 4.06 min, p = 0.185). One sigmoid colon cancer was detected per group. The single-use device showed inferior image quality and far-field brightness (both p < 0.001).

CONCLUSIONS: In this exploratory randomized trial, the novel single-use colonoscope demonstrated clinical efficacy and safety profiles comparable to the conventional system. These preliminary findings support its potential for integration into routine screening, pending confirmation in larger noninferiority studies. Chinese Clinical Trial Registry: ChiCTR2400082142.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты