MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/icb.0000000000001438

Медицинская библиотека · Retinal cases & brief reports · 2024

MACULAR SLING: A CUSTOMIZABLE METHOD FOR MACULAR BUCKLING USING AVAILABLE ELEMENTS.

Clark Andrew, Souverein Erik A, Rootman Daniel B, Yang Dong, Kreiger Allan E, Nagiel Aaron

СтатьяКлинический случайПеревод в очереди

Аннотация

PURPOSE: Macular buckling surgery is used to treat certain cases of myopic traction maculopathy but is rarely performed in the United States. One of the main factors limiting its use is the lack of commercially available buckling elements. Here, we describe a novel technique for creating an effective macular buckle using readily obtainable buckling materials.

METHODS

By using a traditional circumferential 41 band as the anchoring point around the globe, a 240 band can then be attached and oriented posteriorly along the superonasal-inferotemporal axis. This posterior 240 band is then used to guide a grooved sponge (509G) under the macula to create a customizable and titratable tamponade effect along the posterior pole. This approach was used to provide external support in the case of a recurrent, complex tractional retinal detachment which had failed multiple prior vitrectomy-based repairs.

RESULTS

Placement of the macular sling resolved the patient's recurrent retinal detachment with return of the visual acuity to her preoperative baseline. There have been no adverse effects related to the surgery aside from a large hyperopic shift due to the buckle effect on the macula. We believe the technical and material complexity of this technique is comparable with that of more common scleral buckling techniques.

CONCLUSION

This macular sling technique can be used to create an effective posterior buckle without requiring specialized materials.

Для цитирования: Clark Andrew, Souverein Erik A, Rootman Daniel B, Yang Dong, Kreiger Allan E, Nagiel Aaron. MACULAR SLING: A CUSTOMIZABLE METHOD FOR MACULAR BUCKLING USING AVAILABLE ELEMENTS.. Retinal cases & brief reports. 2024. DOI: 10.1097/icb.0000000000001438.