MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.gie.2024.11.004

Медицинская библиотека · Gastrointestinal endoscopy · 2024

Nationwide multicenter prospective study on the usefulness, safety, and acceptability of colon capsule endoscopy in Japan.

Hotta Naoki, Ohmiya Naoki, Hiraga Hiroto, Nakaji Konosuke, Osawa Satoshi, Omori Takafumi, Mitsufuji Shoji, Hosoe Naoki, Nouda Sadaharu, Kobayashi Taku, Nakamura Masanao, Oka Shiro, Nonogaki Koji, Baba Yukiko, Mukai Rieko, Matsumoto Hiroshi, Ikebuchi Yuichiro, Shimada Masaaki, Togashi Kazutomo, Katsuki Shinichi, Sasaki Yu, Sawada Ryoichi, Kawano Seiji, Furuta Takahisa, Tajiri Hisao, Tanaka Shinji, ColoCam-J Study Group

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND AND AIMS: We determined the factors influencing total capsule colonoscopy, adequate cleansing, and detectability of second-generation colon capsule endoscopy (CCE) for colorectal polyps or tumors (CRTs), adverse events, and acceptability.

METHODS

Among 44 Japanese hospitals, 1006 patients with suspected or documented colorectal diseases who underwent CCE were enrolled prospectively.

RESULTS

The total capsule colonoscopy rate was 86.1%. Age younger than 63 years (adjusted odds ratio [aOR], 1.525), male sex (aOR, 1.496), inflammatory bowel disease (aOR, 1.889), lavage intake on day -1 (aOR, 1.625), ≥1800-mL lavage intake on day 0 (aOR, .595), prokinetics on day 0 (aOR, .608), and ≥30-mL castor oil booster on day 0 (aOR, 1.734) were significant independent predictors. The overall adequate cleansing rate was 65.5%. Constipation (aOR, .527), lavage intake on day -1 (aOR, 1.822), laxative intake on day -1 (aOR, 2.616), and ≥1900-mL lavage intake on day 0 (aOR, 1.449) were significant independent predictors. The detection rates for patients with CRTs ≥6 mm and ≥10 mm were 92% (95% confidence interval, 84-97) and 89% (95% confidence interval, 78-96), respectively. Inadequate cleansing in the ascending colon (aOR, .184), ≥6-mm CRT in the transverse colon (aOR, 4.703), and ≥6-mm CRT in the left-sided colon (aOR, 32.013) were significant independent predictors. CCE retention occurred in 2 patients (.20%) requiring endoscopic and surgical interventions. In total, 63% of patients desired CCE for their next colonoscopy.

CONCLUSIONS

CCE was relatively safe, well tolerated, and useful for detecting colorectal lesions when adequate bowel preparation was made. (Clinical trial registration number: UMIN000021936.).

Для цитирования: Hotta Naoki, Ohmiya Naoki, Hiraga Hiroto, Nakaji Konosuke, Osawa Satoshi, Omori Takafumi, Mitsufuji Shoji, Hosoe Naoki, Nouda Sadaharu, Kobayashi Taku, Nakamura Masanao, Oka Shiro, Nonogaki Koji, Baba Yukiko, Mukai Rieko, Matsumoto Hiroshi, Ikebuchi Yuichiro, Shimada Masaaki, Togashi Kazutomo, Katsuki Shinichi, Sasaki Yu, Sawada Ryoichi, Kawano Seiji, Furuta Takahisa, Tajiri Hisao, Tanaka Shinji, ColoCam-J Study Group. Nationwide multicenter prospective study on the usefulness, safety, and acceptability of colon capsule endoscopy in Japan.. Gastrointestinal endoscopy. 2024. DOI: 10.1016/j.gie.2024.11.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.