Evaluation of infrapatellar fat pad elasticity in knee osteoarthritis using IVIM-DWI-based virtual MR elastography: repeatability and reproducibility analysis.

Tan Hui, Fan Qiuju, Yu Yong, Yu Nan, Wang Shaoyu, Guo Shunlin

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Fibrosis of the infrapatellar fat pad (IPFP) leads to changes in its stiffness, which may impact knee osteoarthritis. However, few studies have utilized virtual MR elastography to assess the variations of the IPFP. This study aimed to evaluate the value of intravoxel incoherent motion diffusion weighted imaging (IVIM-DWI)-based virtual MR elastography (vMRE) in the IPFP by assessing the test-retest repeatability, as well as intra- and inter-observer reproducibility.

METHODS

A total of 71 subjects underwent IVIM-DWI examinations, which were conducted twice with an interval of 30-60 min using an 18-channel knee coil at 3T. Shifted apparent diffusion coefficient (sADC) was calculated from two different sets of b-values (b = 200/800 sec/mm2 and 200/1500 sec/mm2) and then converted to IVIM-DWI MRI-based virtual shear modulus (μdiff_800 and μdiff_1500). Two readers independently delineated regions of interest (ROI) within the IPFP on the vMRE stiffness map to obtain the mean and standard deviation (SD) values of μdiff. Short-term test-retest repeatability, as well as intra- and inter-observer agreement were assessed using the intra-class correlation coefficient (ICC), the coefficient of variation (CoV), and Bland-Altman limits of agreement (LoA).

RESULTS

The mean and SD values of μdiff_1500, along with the mean value of μdiff_800 exhibited excellent intra- and inter-observer reproducibility agreement (ICC ≥ 0.90 and CoV ≤ 10%, P˂ 0.001). The intra- and inter-observer ICCs for the mean values of μdiff_800 were 0.917 and 0.901, respectively, while the ICCs for the SD values of μdiff_800 were 0.870 and 0.863, with CoV exceeding 10% (P˂ 0.001). The test-retest repeatability of the average value of μdiff_1500 was excellent (ICC = 0.902; CoV = 6.8%) compared to μdiff_800 (ICC = 0.877; CoV = 15.3%). Test-retest repeatability of SD for μdiff_1500 was good (ICC = 0.803; CoV = 11.5%) in comparison to SD for μdiff_800 (ICC = 0.796; CoV = 13.5%).

CONCLUSIONS

IVIM-DWI-based vMRE demonstrated significant potential as a reliable tool for measuring tissue elasticity in the IPFP, exhibiting higher repeatability for μdiff_1500 than for μdiff_800.

Для цитирования: Tan Hui, Fan Qiuju, Yu Yong, Yu Nan, Wang Shaoyu, Guo Shunlin. Evaluation of infrapatellar fat pad elasticity in knee osteoarthritis using IVIM-DWI-based virtual MR elastography: repeatability and reproducibility analysis.. BMC musculoskeletal disorders. 2025. DOI: 10.1186/s12891-025-08660-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.