m+Medelevator.RU
← Поиск публикаций
BMC medical imaging · 2025

CVT-HNet: a fusion model for recognizing perianal fistulizing Crohn's disease based on CNN and ViT.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Li Lanlan, Wang Ziyue, Wang Chongyang, Chen Tao, Deng Ke, Wei Hong'an, Wang Dabiao, Li Juan, Zhang Heng

Аннотация

BACKGROUND: Accurate identification of anal fistulas is essential, as it directly impacts the severity of subsequent perianal infections, prognostic indicators, and overall treatment outcomes. Traditional manual recognition methods are inefficient. In response, computer vision methods have been adopted to improve efficiency. Convolutional neural networks(CNNs) are the main basis for detecting anal fistulas in current computer vision techniques. However, these methods often struggle to capture long-range dependencies effectively, which results in inadequate handling of images of anal fistulas.

METHODS: This study proposes a new fusion model, CVT-HNet, that integrates MobileNet with vision transformer technology. This design utilizes CNNs to extract local features and Transformers to capture long-range dependencies. In addition, the MobileNetV2 with Coordinate Attention mechanism and encoder modules are optimized to improve the precision of detecting anal fistulas.

RESULTS: Comparative experimental results show that CVT-HNet achieves an accuracy of 80.66% with significant robustness. It surpasses both pure Transformer architecture models and other fusion networks. Internal validation results demonstrate the reliability and consistency of CVT-HNet. External validation demonstrates that our model exhibits commendable transportability and generalizability. In visualization analysis, CVT-HNet exhibits a more concentrated focus on the region of interest in images of anal fistulas. Furthermore, the contribution of each CVT-HNet component module is evaluated by ablation experiments.

CONCLUSION: The experimental results highlight the superior performance and practicality of CVT-HNet in detecting anal fistulas. By combining local and global information, CVT-HNet demonstrates strong performance. The model not only achieves high accuracy and robustness but also exhibits strong generalizability. This makes it suitable for real-world applications where variability in data is common.These findings emphasize its effectiveness in clinical contexts.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты