Four-Flanged Intrascleral Intraocular Lens Fixation Technique: No Flaps, No Knots, No Glue.

Canabrava Sergio, Canêdo Domingos Lima Ana Carolina, Ribeiro Guilherme

СтатьяTechnical ReportПеревод в очереди

Аннотация

PURPOSE: To develop a novel, sutureless, single-piece, nonfoldable intraocular lens (IOL) intrascleral fixation technique based on the existing Malbran IOL scleral fixation and Yamane double-needle techniques.

METHODS

The novel method uses a 5.0 polypropylene suture and a bipolar cautery to create 2 flanges in the eyelets of the IOL and 2 flanges outside to insert inside the scleral tunnel and thus fixate the IOL.

RESULTS

This technique had been applied in 4 patients with aphakia after phacoemulsification complications. The mean preoperative and postoperative corrected distance visual acuities were 0.45 ± 0.17 and 0.67 ± 0.27 (Snellen decimal units), respectively.

CONCLUSIONS

The 4-flanged technique improves and simplifies the existing single-piece, nonfoldable IOL intrascleral fixation techniques.

Для цитирования: Canabrava Sergio, Canêdo Domingos Lima Ana Carolina, Ribeiro Guilherme. Four-Flanged Intrascleral Intraocular Lens Fixation Technique: No Flaps, No Knots, No Glue.. Cornea. 2020. DOI: 10.1097/ico.0000000000002185.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.