m+Medelevator.RU
← Поиск публикаций
Respiratory research · 2026

Ultra-high-resolution synchrotron phase-contrast CT enables microstructural pulmonary imaging at clinical dose levels.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Benke Claudia Victoria, Reiser Johanna, D'Amico Lorenzo, Sagar Md Motiur Rahman, Sodini Nicola, Dreossi Diego, Contillo Adriano, Longo Elena, Prašek Marko, Stern Stephan, Baratella Elisa, Cova Maria Assunta, Confalonieri Marco, Confalonieri Paola, Zanconati Fabrizio, D'Errico Stefano, Radaelli Davide, Bruscagin Tommaso, Bonazza Deborah, Bayat Sam, Nolte Philipp, Neubert Lavinia, Petzold-Mügge Christina, Werlein Christopher, Knudsen Lars, Shin Hoen-Oh, Kamp Jan-Christopher, Hosseini Ali Seif Amir, Wagner Willi Linus, Wielpütz Mark Oliver, Biederer Jürgen, Kauczor Hans-Ulrich, Alves Frauke, Tromba Giuliana, Dullin Christian

Аннотация

BACKGROUND: Ultra-high-resolution propagation-based synchrotron phase-contrast CT is an emerging technique for lung imaging. However, its feasibility and diagnostic potential at radiation doses comparable to those used in standard clinical procedures has yet to be established. This study aims to evaluate the performance of phase-contrast CT in comparison with state-of-the-art high-resolution multislice CT and bronchoscopy, and to validate its diagnostic accuracy histologically using porcine and, for the first time, human lung specimens. METHODS: Phase-contrast CT experiments were conducted at the Italian synchrotron using lung specimens mounted in a custom-made anthropomorphic chest phantom. Imaging utilized two photon-counting detectors under various acquisition settings, followed by artificial intelligence-based denoising. Sequential imaging by phase-contrast CT, multislice CT, and bronchoscopy was performed prior to formaldehyde vapor fixation and histological dissection. Image quality was assessed quantitatively (contrast-to-noise ratio, edge sharpness, power spectra) and qualitatively via radiological scoring across 14 criteria. RESULTS: Phase-contrast CT achieved effective pixel sizes of 0.067 mm (Hydra detector) and 0.038 mm (LAMBDA detector), at radiation doses near full-dose multislice CT (≈ 12 mGy). Denoising improved contrast without major loss of edge sharpness. Radiological scoring showed phase-contrast CT outperformed multislice CT in visualizing peripheral airways and fine parenchymal structures. Histological validation confirmed imaging accuracy. Limitations from source spot size (≈ 200 μm) were noted but did not prevent significant diagnostic improvements. CONCLUSIONS: Phase-contrast CT, combined with artificial intelligence-based denoising, offers detailed, non-invasive imaging of lung microstructures at clinically relevant radiation doses. It complements multislice CT, holds potential for clinical adoption in advanced pulmonary diagnostics, and may reduce reliance on invasive biopsies.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты