Pulsed electron avalanche knife: new technology for cataract surgery.

Priglinger Siegfried G, Palanker Daniel, Alge Claudia S, Kreutzer Thomas C, Haritoglou Christos, Grueterich Martin, Kampik Anselm

Оценочное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The pulsed electron avalanche knife (PEAK-fc) is a new pulsed electrosurgical device that allows for precise, "cold" and traction-free tissue dissection.

AIM: To evaluate the surgical applicability, safety and potential complications of PEAK-fc in complicated cataract surgery.

METHODS

The study included five children with congenital cataracts, two patients with advanced senile cataracts, six adults with mature cataracts, three of them with posterior iris synechia, three patients with post-traumatic cataracts with zonulolysis, one patient with intumescent traumatic cataract and three patients with massive anterior capsule opacification. Anterior and posterior capsulotomies, iris synechiolysis, dissection of anterior capsule opacification and fibrotic scar tissue were performed. PEAK-fc was set at voltages of 500-700 V, pulse duration of 0.1 m and repetition rate of 40-100 Hz.

RESULTS

Anterior and posterior capsulotomies were successfully and safely performed in all eyes. The edges of capsulotomies appeared sharp, showing only limited collateral damage. PEAK-fc worked best by just gently touching the capsule, thereby avoiding tractional forces or pressure on the lens capsule. Posterior iris synechiae could be released and anterior capsule opacification was dissected without complications.

CONCLUSIONS

PEAK-fc is a very helpful cutting device for complicated cases of cataract surgery, especially for mature and congenital cataracts, traumatic zonulolysis or anterior segment complications after intraocular inflammation.

Для цитирования: Priglinger Siegfried G, Palanker Daniel, Alge Claudia S, Kreutzer Thomas C, Haritoglou Christos, Grueterich Martin, Kampik Anselm. Pulsed electron avalanche knife: new technology for cataract surgery.. The British journal of ophthalmology. 2007. DOI: 10.1136/bjo.2006.109546.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.