m+Medelevator.RU
← Поиск публикаций
COPD · 2025

Efficacy and Safety of Lung Volume Reduction with Endobronchial Coil #2 and Coil #4 Results of the German Emphysema Registry-Lungenemphysemregister e.V.

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Grah Christian, Oei Shiao Li, Krist Joanna, Wiesemann Björn, Schmidt Bernd, Fertl Andreas, Schwick Björn, Hübner Ralf-Harto, Becke Birgit, Franke Karl-Josef, Geltner Christian, Eisenmann Stephan, Stanzel Franz, Barten-Neiner Grit, Sgarbossa Thomas, Blazejczyk Katarzyna, Wüstefeld Hannah

Аннотация

BACKGROUND: Clinical trials have shown beneficial results from lung volume reduction with endobronchial coils in patients with emphysema, but comprehensive safety data are not yet available for a new coil type, Coil #4. The objective of this study is to generate real-world data (RWD) on the safety and efficacy of endobronchial Coil #2 and Coil #4.

METHODS: This is a cohort study of prospectively collected data from the multicenter German Lung Emphysema Registry e.V. (LE-Registry) for patients with advanced lung emphysema undergoing lung volume reduction. All patients treated with Coil #2 or Coil #4 were evaluated at baseline and at 3 months for pulmonary function tests (FEV1, FVC, RV, DLCO, pCO2), exercise capacity, quality of life (mMRC, CAT, SGRQ), and adverse events. Descriptive statistics were used to analyze response rates and changes in clinical outcomes.

RESULTS: Data from 73 patients (37 Coil #2, 36 Coil #4) enrolled between 2017 and 2024 were evaluated. At 3 months, outcome data were available for 32 Coil #2 and 26 Coil #4 patients. In the Coil #2 cohort significant improvements in RV and SGRQ were observed. The Coil #4 cohort shows significant improvements in FVC, RV, SGRQ, and CAT. Complications occurred in 37% of Coil #2 and 37% of Coil #4 patients, with 26% of patients treated with Coil #4 experiencing pneumothorax.

CONCLUSIONS: The outcomes observed in this RWD study are consistent with other published coil studies. The higher pneumothorax rate with Coil #4 is surprising and should be minimized by adapting the technique.

TRIAL REGISTRATION: DRKS00021207 registered on 29/05/2020.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты