MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2025.07.019

Медицинская библиотека · JACC. Cardiovascular interventions · 2025

Early U.S. Commercial Experience With a Novel Transcatheter Edge-to-Edge Repair System: Insights From Real-World Data.

Waggoner Thomas, Garcia Santiago, Chakravarty Tarun, Makar Moody, Latib Azeem, Kipperman Robert M, Zahr Firas, Hanson Ivan, Sinha Anjan K, Sharma Rahul P, Depta Jeremiah P, Castellanos Jorge A, Kodali Susheel, Krishnaswamy Amar, Whisenant Brian, Menees Daniel, Lim D Scott, Gilani Fahad, Sanchez Carlos E, Gheewala Neil, Gada Hemal, Kapadia Samir, Ramanathan P Kasi, Shah Pinak B, Renard Brian, Theodos Gus, Yaryura Ricardo, Gardner Blake, Steinberg Daniel H, Gnall Eric, Kaddissi Georges, Chhatriwalla Adnan K, Frangieh Antonio H, Eleid Mackram F, Géneréux Philippe, Saxon John T, Villablanca Pedro, Matar Fadi, Agarwal Himanshu, Chetcuti Stanley, Frisoli Tiberio, Makkar Raj

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The PASCAL Precision transcatheter valve repair system provides a new option for treating prohibitive surgical risk patients with significant, symptomatic degenerative mitral regurgitation (DMR).

OBJECTIVES

The authors report early U.S. commercial experience with the PASCAL Precision system.

METHODS

Patients with DMR treated with the PASCAL Precision system in the United States were analyzed from the STS/ACC TVT Registry. Procedural, clinical, echocardiographic, functional, and quality-of-life outcomes to 30 days were assessed. All outcomes, including echocardiographic assessments, were site-assessed.

RESULTS

In 1,995 DMR patients, the median age was 81.6 years, and 57.0% were male. Median STS-PROM for mitral valve repair was 3.6%, and 69.4% were in NYHA functional class III/IV. Mixed etiology (DMR + other etiology) was present in 11.4%, and 66.9% had complex anatomy (annular/leaflet calcification, mitral valve area <4 cm2, bileaflet flail/prolapse/tethering, or mitral stenosis). The device was successfully implanted in 97.7%. MR reduction was significant at 30 days with 94.2% achieving ≤moderate MR and 72.6% ≤mild MR (P < 0.001 vs baseline). Patients experienced significant functional and quality-of-life improvements with a mean 21.0-point increase in Kansas City Cardiomyopathy Questionnaire score and 84.6% in NYHA functional class I/II (all P < 0.001). Mitral valve reintervention and single-leaflet device attachment rates were 0.4% and 0.5%, respectively, and all-cause mortality, cardiovascular mortality, and heart failure readmission rates were 2.2%, 1.2%, and 2.6%, respectively, at 30 days.

CONCLUSIONS

Early U.S. STS/ACC TVT Registry commercial experience confirms the safety and effectiveness of the novel PASCAL Precision system in the treatment of a broad population of real-world DMR patients.

Для цитирования: Waggoner Thomas, Garcia Santiago, Chakravarty Tarun, Makar Moody, Latib Azeem, Kipperman Robert M, Zahr Firas, Hanson Ivan, Sinha Anjan K, Sharma Rahul P, Depta Jeremiah P, Castellanos Jorge A, Kodali Susheel, Krishnaswamy Amar, Whisenant Brian, Menees Daniel, Lim D Scott, Gilani Fahad, Sanchez Carlos E, Gheewala Neil, Gada Hemal, Kapadia Samir, Ramanathan P Kasi, Shah Pinak B, Renard Brian, Theodos Gus, Yaryura Ricardo, Gardner Blake, Steinberg Daniel H, Gnall Eric, Kaddissi Georges, Chhatriwalla Adnan K, Frangieh Antonio H, Eleid Mackram F, Géneréux Philippe, Saxon John T, Villablanca Pedro, Matar Fadi, Agarwal Himanshu, Chetcuti Stanley, Frisoli Tiberio, Makkar Raj. Early U.S. Commercial Experience With a Novel Transcatheter Edge-to-Edge Repair System: Insights From Real-World Data.. JACC. Cardiovascular interventions. 2025. DOI: 10.1016/j.jcin.2025.07.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.