MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40510-025-00578-y

Медицинская библиотека · Progress in orthodontics · 2025

Biomechanical effects of attachment designs in maxillary first molar mesialization with clear aligners: a finite element study.

Vatansever Resul, Gurel Hakan Gurcan, Koc Osman

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Clear aligners face biomechanical limitations in complex tooth movements, particularly first molar mesialization, despite attachment use. Finite element analysis (FEA) can elucidate optimal attachment designs for force delivery.

OBJECTIVES

To compare displacement patterns and stress distribution during maxillary first molar mesialization using four attachment designs via 3D FEA.

METHODS

A maxillary model (MRI-derived) was created with periodontal ligament (PDL), alveolar bone, and clear aligner (0.75 mm thickness). Five scenarios were simulated: no attachment (Model-I), vertical rectangular (Model-II), horizontal rectangular (Model-III), optimized double semi-ellipsoidal (Model-IV), and Yin-Yang attachments (Model-V). Mesial displacement (0.5 mm) was applied, and deformation/stress were analyzed using ANSYS Workbench.

RESULTS

Model-IV (optimized attachment) demonstrated the least first molar tipping, evidenced by its lowest total mesial crown displacement (0.319 mm), and provided the best mesiodistal control. Conversely, Model-I (no attachment) exhibited the highest tipping, with a total mesial crown displacement of 0.376 mm. Yin-Yang attachments (Model-V) significantly reduced buccal displacement by 92% compared to Model-I. Horizontal rectangular attachments minimized rotational movement.

CONCLUSIONS

Optimized double semi-ellipsoidal attachments provide superior first molar mesialization control, while Yin-Yang designs enhance buccal-lingual stability. Attachment geometry critically influences aligner efficacy.

Для цитирования: Vatansever Resul, Gurel Hakan Gurcan, Koc Osman. Biomechanical effects of attachment designs in maxillary first molar mesialization with clear aligners: a finite element study.. Progress in orthodontics. 2025. DOI: 10.1186/s40510-025-00578-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.