MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.13990

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2020

Atrial fibrillation post central retinal artery occlusion: Role of implantable loop recorders.

Watson Ryan A, Wellings Jennifer, Hingorani Rittu, Zhan Tingting, Frisch Daniel R, Ho Reginald T, Pavri Behzad B, Sergott Robert C, Greenspon Arnold J

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study evaluated the risk of subclinical atrial fibrillation (AF) in patients with central retinal artery occlusion (CRAO) compared to those with cryptogenic stroke using implantable loop recorders (ILR).

METHODS

We conducted a retrospective analysis of 273 consecutive patients who had ILRs inserted at our institution for either cryptogenic stroke (n = 227) or CRAO (n = 46). Our primary endpoint was a time to event analysis for the new diagnosis of AF by ILR. Univariable and multivariable Cox proportional hazard models were used to determine the predictors of time-to-AF.

RESULTS

A total of 64 patients were found to have newly diagnosed AF by remote monitoring of the ILR. AF was detected in 57 of 227 (25%) cryptogenic stroke patients by the end of a maximum 5.1 years follow-up and in seven of 46 (15%) CRAO patients by the end of a maximum 3.6 years follow-up (P = .215, log-rank test). The Kaplan-Meier estimates for freedom from AF was 59.4% for CRAO and 66.6% for cryptogenic stroke (P = NS, log-rank test). Baseline variables predicting AF included older patients, higher CHADS2 VASC score, longer PR interval on initial EKG evaluation, and mitral annular calcification on transthoracic echocardiogram.

CONCLUSIONS

Patients with CRAO are at risk for subclinical AF, similar to those with cryptogenic stroke. Long-term monitoring to detect AF may lead to changes in pharmacotherapy to reduce the risk for subsequent stroke.

Для цитирования: Watson Ryan A, Wellings Jennifer, Hingorani Rittu, Zhan Tingting, Frisch Daniel R, Ho Reginald T, Pavri Behzad B, Sergott Robert C, Greenspon Arnold J. Atrial fibrillation post central retinal artery occlusion: Role of implantable loop recorders.. Pacing and clinical electrophysiology : PACE. 2020. DOI: 10.1111/pace.13990.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.