m+Medelevator.RU
← Поиск публикаций
Gait & posture · 2024

Validation of ActiGraph and Fitbit in the assessment of energy expenditure in Huntington's disease.

Наблюдательное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Simón-Vicente Lucía, Rodríguez-Fernández Alejandro, Rivadeneyra-Posadas Jéssica, Soto-Célix María, Raya-González Javier, Castillo-Alvira Daniel, Calvo Sara, Mariscal Natividad, García-Bustillo Álvaro, Aguado Laura, Cubo Esther

Аннотация

BACKGROUND: Consumer and research activity monitors have become popular because of their ability to quantify energy expenditure (EE) in free-living conditions. However, the accuracy of activity trackers in determining EE in people with Huntington's Disease (HD) is unknown.

RESEARCH QUESTION: Can the ActiGraph wGT3X-B or the Fitbit Charge 4 accurately measure energy expenditure during physical activity, in people with HD compared to Indirect Calorimetry (IC) (Medisoft Ergo Card)?

METHODS: We conducted a cross-sectional, observational study with fourteen participants with mild-moderate HD (mean age 55.7 ± 11.4 years). All participants wore an ActiGraph and Fitbit during an incremental test, running on a treadmill at 3.2 km/h and 5.2 km/h for three minutes at each speed. We analysed and compared the accuracy of EE estimates obtained by Fitbit and ActiGraph against the EE estimates obtained by a metabolic cart, using with Intra-class correlation (ICC), Bland-Altman analysis and correlation tests.

RESULTS: A significant correlation and a moderate reliability was found between ActiGraph and IC for the incremental test (r = 0.667)(ICC=0.633). There was a significant correlation between Fitbit and IC during the incremental test (r = 0.701), but the reliability was poor at all tested speeds in the treadmill walk. Fitbit significantly overestimated EE, and ActiGraph underestimated EE compared to IC, but ActiGraph estimates were more accurate than Fitbit in all tests.

SIGNIFICANCE: Compared to IC, Fitbit Charge 4 and ActiGraph wGT3X-BT have reduced accuracy in estimating EE at slower walking speeds. These findings highlight the need for population-specific algorithms and validation of activity trackers.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты