MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4314/mmj.v37i2.8

Медицинская библиотека · Malawi medical journal : the journal of Medical Association of Malawi · 2025

Deep learning-based reconstruction improves image quality in low-dose head CT angiography.

Huang Xin, Shang Jin, Xiao Yao, Hou Wei, Mu Guangrui, Li Daliang, Qian Hua, Li Junying

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

This study aimed to compare the image quality of filtered back projection (FBP), adaptive statistical iterative reconstruction-Veo (ASIR-V) and the deep learning image reconstruction (DLIR) algorithms in low-dose head CT angiography (CTA).

METHODS

This prospective study was conducted on 25 patients undergoing head CTA using a 256-slice CT scanner. Patients received 25 mL of iodine contrast (Iopromide, 370 mg I/mL, 3.0 mL/s). Images were reconstructed using DLIR with high settings (DLIR-H) and medium settings (DLIR-M), FBP, and ASIR-V with a blending factor of 50% (ASIR-V 50%). CT values, standard deviations, signal-to-noise ratios (SNR), and contrast-to-noise ratios (CNR) were measured at the basal ganglia, posterior cranial fossa, center of semiovale, and middle cerebral artery. The edge rise slope (ERS) of the middle cerebral artery rim was measured to assess vessel clarity. Image noise, vessel edge definition, and overall quality were scored on a 5-point scale, while sharpness and clarity were rated on a 4-point scale.

RESULTS

FBP images exhibited the highest image noise, as reflected by SD values. DLIR, especially DLIR-H, showed superior noise reduction compared to ASIR-V 50%. SNR followed this trend: FBP < ASIR-V 50% < DLIR-M < DLIR-H. Spatial resolution, measured by ERS for vessel wall clarity, was higher in DLIR images compared to in ASIR-V 50%. DLIR outperformed conventional iterative algorithms in balancing noise reduction and edge clarity, with both DLIR-M and DLIR-H achieving better subjective scores for noise, edge definition, and sharpness than ASIR-V 50% and FBP.

CONCLUSION

DLIR in low-dose head CTA could reduces image noise, preserve natural texture, and enhance image clarity compared with ASIR-V and FBP methods.

Для цитирования: Huang Xin, Shang Jin, Xiao Yao, Hou Wei, Mu Guangrui, Li Daliang, Qian Hua, Li Junying. Deep learning-based reconstruction improves image quality in low-dose head CT angiography.. Malawi medical journal : the journal of Medical Association of Malawi. 2025. DOI: 10.4314/mmj.v37i2.8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.