MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fneur.2025.1678450

Медицинская библиотека · Frontiers in neurology · 2025

Accuracy of computed tomography perfusion-defined ischemic core and follow-up infarction after basilar artery thrombectomy.

Chen Pengjun, Li Xia, Huang Yechao, Hui Junguo, Rao Jie, Zhang Wenya, Shang Lijun, Chen Xiao, Gao Ruijie, Zhou Jinwei, Xia Shuiwei, Ding Qiaoling, Ji Jiansong

СтатьяПеревод в очереди

Аннотация

PURPOSE: Accurate identification of computed tomography (CT) perfusion ischemic core in patients with basilar artery occlusion (BAO) on admission remains challenging despite its critical role in prognostic prediction and treatment decision-making. We aimed to define the optimal threshold for identifying the ischemic core by assessing agreement in lesion extent and spatial distribution using Syngo.via.

METHODS

We retrospectively analyzed 91 patients with BAO who achieved successful recanalization after endovascular thrombectomy at our center. The ischemic core was estimated using the following thresholds: cerebral blood flow (CBF) < 10 or 15 mL/100 g/min by Syngo.via, cerebral blood volume < 1.2 mL/100 mL by Syngo.via, and time to maximum > 10 s by RAPID. The Posterior Circulation Alberta Stroke Program Early CT Score was used to assess the extent of the infarction. Statistical analyses included the intraclass correlation coefficient (ICC) and receiver operating characteristic analyses.

RESULTS

The CBF < 10 mL/100 g/min threshold demonstrated good agreement in extent with follow-up infarction (ICC: 0.81 [95% confidence intervals 0.72-0.87]), with overestimation or underestimation being the most uncommon (n = 9). For the detection of midbrain, pontine, and cerebellar infarction, this threshold yielded the best performance with the area under the curve ranging from 0.79 (midbrain, 0.66-0.93; p < 0.001) to 0.90 (pons, 0.83-0.98; p < 0.001).

CONCLUSION

In patients with BAO after successful recanalization, the optimal threshold for the ischemic core was a CBF < 10 mL/100 g/min. This threshold may serve as a reliable imaging biomarker, aiding in the prediction of tissue outcomes and treatment decision-making.

Для цитирования: Chen Pengjun, Li Xia, Huang Yechao, Hui Junguo, Rao Jie, Zhang Wenya, Shang Lijun, Chen Xiao, Gao Ruijie, Zhou Jinwei, Xia Shuiwei, Ding Qiaoling, Ji Jiansong. Accuracy of computed tomography perfusion-defined ischemic core and follow-up infarction after basilar artery thrombectomy.. Frontiers in neurology. 2025. DOI: 10.3389/fneur.2025.1678450.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.