DOI 10.1007/s11604-025-01909-z

Медицинская библиотека · Japanese journal of radiology · 2026

Comparison of conventional 512-matrix CT images with Swin2SR-based 2048-matrix images in the visualization and diagnosis of lung nodules.

Zhang Yaping, Wang Ai, Li Qingyao, Zhang Lu, Wang Lingyun, Pan Zhijie, Hu Yanfei, Xie Xueqian

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

PURPOSE: Clear visualization and diagnosis of lung nodules depend on the spatial resolution of CT images. Transformer-based generative neural networks can generate super-resolution images. To compare the diagnostic value of standard CT images of 512 × 512 pixels and Swin2SR-based super-resolution images of 2048 × 2048 pixels for lung cancer.

MATERIALS AND

METHODS

The transformer-based Swin2SR model, which can upscale standard 512 × 512 pixel CT images to 2048 × 2048 super-resolution images, was validated with four retrospective datasets, three of which were patient data at three hospitals from January 2018 to December 2020, and another was the public Non-Small Cell Lung Cancer-Radiogenomics dataset. Lung nodules < 3 cm were included to validate the image quality of super-resolution images, and to compare the ability of standard and super-resolution images to display malignancy-associated imaging features and to diagnose lung cancer.

RESULTS

1161 nodules (663 malignant and 498 non-malignant) in 1161 subjects (age 60.2 ± 9.9 years, 653 males [56.2%]) were included. Swin2SR-based super-resolution images of these nodules had higher image scores (image quality, sharpness and noise) than standard images (p < 0.001). Among the malignancy-associated imaging features, the Swin2SR-based super-resolution images showed significantly more bubble-like lucency and air bronchogram than standard images (p < 0.001). Of the 663 histologically confirmed malignant nodules, 577 (87.0%) were considered malignant on Swin2SR-based super-resolution images, which was significantly higher than the 529 (79.8%) nodules on standard images (P = 0.037). The accuracy of Swin2SR-based super-resolution images and standard images in diagnosing lung cancer was 0.83 (95% CI 0.81-0.85) and 0.79 (0.76-0.81), respectively.

CONCLUSION

Swin2SR-based super-resolution 2048 × 2048 pixel CT images can clearly show the malignancy-associated imaging features of lung nodules and improve the diagnostic of lung cancer.

Для цитирования: Zhang Yaping, Wang Ai, Li Qingyao, Zhang Lu, Wang Lingyun, Pan Zhijie, Hu Yanfei, Xie Xueqian. Comparison of conventional 512-matrix CT images with Swin2SR-based 2048-matrix images in the visualization and diagnosis of lung nodules.. Japanese journal of radiology. 2026. DOI: 10.1007/s11604-025-01909-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.