Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025

Comparative study of nanosecond and microsecond pulsed field ablation for pulmonary vein isolation in preclinical models.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Xie Hai-Yang, Li Jiajie, Wu Jianhua, Chen Yuyang, Xie Yong, Tan Jianwen, Wang Jingfeng, Xie Shuanglun

Аннотация

AIMS: Nanosecond pulsed field ablation (nsPFA) has emerged as an alternative in atrial fibrillation (AF) ablation. It leverages the alleviated muscle contractions (MCs) associated with nanosecond pulses, which may reduce complications and anaesthetic requirements compared with conventional microsecond PFA (μsPFA). To pre-clinically compare the safety, efficacy, and MC effects of nsPFA and μsPFA.

METHODS AND RESULTS: Typical parameters were tested for pulmonary vein isolation (PVI) in swine using a novel commercial PFA system with either nsPFA or μsPFA protocols. Procedural outcomes and histological analysis were evaluated at 3-, 30-, and 90-day follow-ups. Electrical stimulation experiments were conducted using various pulse voltages and widths (ranging from nanoseconds to microseconds) to evaluate contractions in swine. nsPFA was non-inferior to μsPFA in terms of PVI safety and efficacy in the follow-up of 18 swine ablation procedures. Both protocols achieved consistent transmural and circumferential lesion creation without damaging adjacent structures such as the oesophagus or causing phrenic nerve block or paralysis. Additionally, nsPFA induced significantly lower MCs than μsPFA did in swine.

CONCLUSION: The nsPFA protocol is a demonstrated potential approach for AF ablation, demonstrating comparable safety and efficacy to μsPFA, with reduced MCs. These findings suggest that nsPFA may offer an equally effective alternative, with significantly reduced MCs, which may translate to lower anaesthesia requirements.