m+Medelevator.RU
← Поиск публикаций
Annals of vascular surgery · 2020

Application of a Reversed Off-the-Shelf Iliac Branched Device Stent in Revascularization of the Renal Artery Originating from the False Lumen.

Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

He Yuan, Zhang Hongpeng, Sun Guoyi, Cao Long, Wang Xinhao, Ge Yangyang, Liu Xiaoping, Jia Xin, Ma Xiaohui, Xiong Jiang, Wu Ye, Wei Ren, Jia Senhao, Guo Wei

Аннотация

Fenestrated/branched endovascular aneurysm repair is a feasible and effective treatment option for patients with postdissection thoracoabdominal/abdominal aneurysm. However, this technique is cumbersome when the target vessel originates from the false lumen. We herein report our primary experiences in utilizing a reversed off-the-shelf iliac branched device (IBD) stent to reconstruct the renal artery originating from the false lumen. This technique was performed in 3 patients (all men; 49, 46, and 45 years old) in our center. After deployment of the main aortic endograft, the distal re-entry in the common iliac artery was dilated by a balloon. The off-the-shelf IBD was then reversely deployed to allow for deployment of the bridging stent graft. Finally, the IBD and the bridging stents were assembled and the IBD was connected to the main graft. No migration of the IBDs occurred, and all target vessels remained patent during follow-up. Utilization of a reversed off-the-shelf IBD for the renal artery originating from the false lumen is a feasible option, especially for patients with specific anatomical characteristics of postdissection aortic aneurysms.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты