m+Medelevator.RU
← Поиск публикаций
Annals of gastroenterology · 2024

Fibrin glue and coats compromise the integrity of colonic anastomosis: an experimental trial on rats.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Voloudakis Nikolaos, Koutelidakis Ioannis, Christoforidis Emmanouil, Atmatzidis Stefanos, Kotoreni Georgia, Papaziogas Basilios, Schizas Dimitrios, Zavos Christos, Papalois Apostolos, Chatzimavroudis Grigorios

Аннотация

BACKGROUND: Anastomotic leak remains a dreaded complication in colorectal surgery. Identifying optimal techniques that minimize its incidence is an active area of investigation. The aim of this experimental study was to evaluate the effect of commonly used hemostatic products on the integrity of colonic anastomoses.

METHODS: Male Wistar rats were randomized into 4 groups. In the control group (A), the anastomosis was performed using the standard hand-sewn technique in the ascending colon. In group B the hand-sewn technique was reinforced with a collagen-fibrinogen patch, in group C with fibrin glue, and in group D with a polyethylene glycol (PEG)-coated oxidized cellulose patch. On the 7th postoperative day, anastomotic bursting pressure measurements were obtained. A specimen surrounding the anastomosis was retrieved for histopathologic evaluation.

RESULTS: Of the 19 rats, 17 survived and 15 were included in the analysis (5 in each of groups A, B and C). Testing in group D was discontinued following adverse events in the preliminary experiments. The mean bursting pressure of the anastomosis was significantly higher in the control group (A: 221±19.41 mmHg, B: 151±14.42 mmHg, and C: 112±13.57 mmHg; P=0.001). Anastomotic healing parameters were not different between groups.

CONCLUSIONS: Although experimental data support the use of sealants in defective anastomoses, in this study the reinforcement of colonic anastomosis with fibrin or oxidized cellulose-PEG sealants did not improve either bursting pressure values or anastomotic healing. More data from robust anastomoses of animals and humans are needed before sealing becomes common clinical practice in colorectal surgery.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты