MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmbbm.2025.107318

Медицинская библиотека · Journal of the mechanical behavior of biomedical materials · 2025

Evaluation of a novel 4-day decellularisation protocol for porcine flexor tendons: A comparative study with a 26-day process.

Haines Victoria, Edwards Jennifer Helen, Herbert Anthony

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

Rupture of the anterior cruciate ligament is a common sports-related injury that lacks intrinsic healing capacity, often necessitating surgical intervention. Our group has developed a new graft biomaterial, the decellularised porcine super flexor tendon (pSFT), designed to mitigate immune rejection post-implantation by removing cellular components. The current 26-day decellularisation process attenuates the mechanical properties of the graft, potentially disrupting the structural micro-cues that influence cell repopulation and integration. This study investigates a shortened 4-day protocol to determine whether mechanical properties are preserved more closely to native, unprocessed tissue. Histological analysis and DNA quantification confirmed effective cell removal for both the 26-day and 4-day protocols. Native, 26-day processed, and 4-day processed grafts were mechanically evaluated through stress relaxation and failure testing. Following stress relaxation testing, several Maxwell-Weichert viscoelastic parameters were found to significantly differ between 26-day and native groups (E0, E1, E2 & τ2), whereas between 4-day and native groups fewer significant differences were found (E1 & E2). Following failure testing, again several parameters were found to significantly differ between 26-day and native groups (PFAIL, UTS, Elinear and εT), whereas between 4-day and native groups only one parameter was significantly different (Elinear). These findings indicate that the 4-day decellularisation process better preserves the native tissue mechanical properties, potentially reducing structural alterations and improving suitability for anterior cruciate ligament replacement.

Для цитирования: Haines Victoria, Edwards Jennifer Helen, Herbert Anthony. Evaluation of a novel 4-day decellularisation protocol for porcine flexor tendons: A comparative study with a 26-day process.. Journal of the mechanical behavior of biomedical materials. 2025. DOI: 10.1016/j.jmbbm.2025.107318.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.