MedElevator Войти в исследования
← Поиск публикаций

DOI 10.12659/pjr.902896

Медицинская библиотека · Polish journal of radiology · 2017

Magnetic Resonance (MR) Imaging Assessment for Glossopharyngeal Neuralgia: Value of Three-Dimensional T2-Reversed MR Imaging (3D-T2R) in Conjunction with Other Modes of 3D MR Imaging.

Nishihara Masashi, Noguchi Tomoyuki, Kawashima Masatou, Azama Shinya, Matsushima Ken, Irie Hiroyuki

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To retrospectively examine the usefulness of gray-scale reversal imaging of T2-weighted images (3D-T2R) in conjunction with other modes of 3D MRI for preoperative assessments in patients with glossopharyngeal neuralgia (GPN) due to neurovascular compression.

MATERIAL/

METHODS

Imaging findings on 3D-T2R, constructive interference in steady state (CISS), and MRA were analyzed with reference to operative charts in 10 patients with GPN.

RESULTS

Offending vessels were associated with the posterior inferior cerebellar artery (PICA) in 9 of 10 patients (90%). Eight of the 10 patients (80%) had offending vessels located at the supraolivary fossette. Of those eight patients, six (75%) had a shift of the ipsilateral vertebral artery to the affected side. Five (42%) and seven (48%) contact points were associated with the root entry/exit zone and the peripheral nerve system segment, respectively. In six of nine contact points (67%), 3D-T2R demonstrated the pathomorphological features at the contact points better than CISS.

CONCLUSIONS

The offending vessels were mostly associated with posterior inferior cerebellar arteries, were frequently located at the supraolivary fossette, and had attachments at the root entry/exit zone and at the peripheral segment of the glossopharyngeal nerve, which was well demonstrated on 3D-T2R.

Для цитирования: Nishihara Masashi, Noguchi Tomoyuki, Kawashima Masatou, Azama Shinya, Matsushima Ken, Irie Hiroyuki. Magnetic Resonance (MR) Imaging Assessment for Glossopharyngeal Neuralgia: Value of Three-Dimensional T2-Reversed MR Imaging (3D-T2R) in Conjunction with Other Modes of 3D MR Imaging.. Polish journal of radiology. 2017. DOI: 10.12659/pjr.902896.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.